manualshive.com logo in svg
background image

383033GB  

Pag. 1  

November 2003 

TECHNICAL INSTRUCTIONS 

 
 

DAYTONA

 

 

 

 

                

 

1-POWER

 

 

 
ENGLISH

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание DAYTONA 1-POWER

Страница 1: ...383033GB Pag 1 November 2003 TECHNICAL INSTRUCTIONS DAYTONA 1 POWER ENGLISH...

Страница 2: ...SMART CARD AUTOMATIC WASHING CYCLE PROCEDURE Pag 19 1 COFFEE GROUP AUTOMATIC TIMED WASHING 2 GROUP MILKER AUTOMATIC WASHING WITH DETERGENT 2 1 GROUP WASHING 2 2 MILKER WASHING DOSE PROGRAMMING PROCEDU...

Страница 3: ...ILKER CLEANING 1 16 COFFEE TEMPERATURE UNIT PROGRAMMING 1 17 CURRENCY DECIMAL NUMBER PROGRAMMING 1 18 MINIMUM CURRENCY UNIT PROGRAMMING 1 19 MAXIMUM CREDIT PROGRAMMING OF THE CREDIT CARD 1 20 COFFEE B...

Страница 4: ...TOOLS MAINTENANCE ALARM 12 COFFEE BOILER TEMPERATURE ALARM TOO HIGH 13 COFFEE BOILER TEMPERATURE ALARM TOO LOW 14 STEAM BOILER TEMPERATURE ALARM TOO HIGH 15 STEAM BOILER TEMPERATURE ALARM TOO LOW 16 F...

Страница 5: ...d altro i documento i della normativa auf das sich diese Erkl rung bezieht mit der den folgenden Norm en oder normativen Dokument en bereinstimmt to which this declaration relates is in conformity wit...

Страница 6: ...the voltage rating of the machine corresponds to that of the power supply and that the power supply is adequate to additional power absorption of the machine After installing the main switch and fuses...

Страница 7: ...ontrols area Stainless steel and ABS plastic for working area and cups tray DAYTONA 1 POWER MACHINE KEYPAD Number of coffee dispensing groups 1 Number of grinders 1 Decaffeinated door 1 Automatic capp...

Страница 8: ...nsing Solution wait until the boiler has reached the set up heating temperature 5 Message of steam boiler heating temperature not reached This message is displayed with the following symbol Cause the...

Страница 9: ...opens to release the air inside the boiler When the steam boiler has been filled up the display shows STEAM BOILER FILLING UP PRESS KEY N 1 AT DISPENSING During this stage the coffee boiler is being...

Страница 10: ...b In case of temporary voltage drop the machine will be automatically turned back to the stage previous to the voltage drop c The display shows SELECT DRINK Where the displayed icon indicates that th...

Страница 11: ...er 2003 MILK BOX HOLDER ASSEMBLY The machine is supplied complete with milk box holder assembly to be fixed to the machine left side in case the refrigerating unit is not being used See drawings to fi...

Страница 12: ...tely enables the dispensing cycle it means that the chosen selection is activated only for a single cup d Pressing any key during dispensing can stop the selected dose In case of a milk based dose pre...

Страница 13: ...ECT DRINK The arrows turned downwards indicate the enabled buttons Press the desired selection button the display shows XXXXXXXX Where XXXXXXXXX is the name of the selected drink WARNING a On Off butt...

Страница 14: ...K WARNING The following configurations are available self with credit card self with coin mechanism In this case the display shows INSERT COINS alternated with INSERT CARD 5 SELF MACHINE WITH COIN MEC...

Страница 15: ...N 13 1x or N 14 2x to modify the level mode Press the key N 12 gost1 to return to the previous environment and or exit Press the key N 16 3 4 5 X to confirm the display shows SELECT DRINK 6 SELF MACHI...

Страница 16: ...nuous dispensing function maximum value is 5 the display shows SELECT DRINK X Where X indicates the number of cycles the machine will automatically carry out for the dose you will select WARNING a If...

Страница 17: ...smart card programming b Owner waiter and credit cards can be converted into smart cards with other functions c Technician s cards cannot be converted into any other smart card Smart card functions 1...

Страница 18: ...an infinite number of cards with credit This card enables dispensing in case the machine has been set as self with credit card 5 Reading writing Smart card This card enables to read all machine data a...

Страница 19: ...al time before the automatic wash switches on see machine parameter management chapter 3 GROUP MILKER AUTOMATIC WASHING WITH DETERGENT To enter the automatic washing mode with detergent proceed as fol...

Страница 20: ...inserted c If the washing cycle is interrupted by any type of operation unrelated to the washing cycle when the machine functioning is set back again the washing cycle will be automatically activated...

Страница 21: ...working day the milker should be dismantled and cleaned by hand To dismantle the milker remove the cover of the coffee milker spout see diagram d The plunged tube needs to be periodically cleaned the...

Страница 22: ...also be activated by keeping a dose key T1 T8 pressed for about 3 seconds if previously configurated as MILKER CLEANING see chapter beverage name programming The display shows MILKER CLEANING When the...

Страница 23: ...ried out Press the key N 12 gost1 to return to the previous environment and or exit The available choices are the following COFFEE BASED DRINKS MILK BASED DRINKS FILTER DRINKS Kaffee creme Schnaps Cap...

Страница 24: ...AMMING MOTOR PUMP XXXXXXXX Where XXXXXXX indicates ENABLED the selected dose will be dispensed by means of the motor pump DISABLED the selected dose will be dispensed without the activation of the mot...

Страница 25: ...SE XX s Where XX s indicates the pause time in seconds carried out by the coffee group cycle after pre infusion cycle WARNING This function has been enabled to optimise the infusion of filter drinks 1...

Страница 26: ...emented to allow steamed and foamed milk to stratify before coffee dispensing 1 13 Programming of steamed milk dispensing time after coffee This level will not be displayed for filter based and coffee...

Страница 27: ...ress hot water button the display shows 2 1 Programming hot water dose for tea DOSE PROGRAMMING HOT WATER WATER XXX X where XXX X indicates the time in seconds during which hot water will be dispensed...

Страница 28: ...oceed as follows Turn the machine ON or OFF Press the key N 15 gost2 the display shows INFO TEMPERATURE SYSTEM COFFEE TEMPERA XX Z STEAM TEMPERA YY Z Where XX C indicates the temperature of the coffee...

Страница 29: ...to confirm entering the next environment the display shows DISPENSING INFO READ DOSE COUNTER SELECT BUTTON Press the key dose whose number of drinks you want to display the display shows DISPENSING IN...

Страница 30: ...decaffeinated dispensed drinks Press the key gost1 to return to the level enabling to select the card number WARNING a If the waiters card is inserted it is not possible to display info about other ca...

Страница 31: ...e of the code to be modified Press the key N 13 1x or N 14 2x to modify the figure Press the key N 16 3 4 5 X to confirm the modification Press the key N 15 gost2 to enter the next level without savin...

Страница 32: ...CHARGE CARD CODE NOT VALID This message is displayed if the inserted card code does not correspond to that of the inserted card Remove the card to be reprogrammed the display shoes CREDIT CHARGE INSER...

Страница 33: ...or exit SYSTEM PROGRAMMING PROGRAMMING GROUP CLEANING SYSTEM PROGRAMMING PROGRAMMING MILKER CLEANING SYSTEM PROGRAMMING SET UP ENCODER SYSTEM PROGRAMMING GROUP MANUAL MOVEMENTS SYSTEM PROGRAMMING TES...

Страница 34: ...e use both of the smart credit card and coin mechanism 1 3 Serial door function MACHINE PARAMETERS SERIAL XXXXXXXX Where XXXXXX indicates Disabled the machine works without connected peripheral I O HA...

Страница 35: ...andard value 1 6 Programming rinse after milk dose RINSE AFTER MILK DOSE XXXXXXXX Where XXXXXXX indicates ENABLED the machine automatically carries out a rinse after milk dose DISABLED the machine doe...

Страница 36: ...ter litre programming MACHINE PARAMETERS WATER FILTER LITRES XXXX Where XXXX indicates the set up number of water filter litres variable value between 0 15000 5000 set up standard value WARNING XXXX T...

Страница 37: ...ammed number of milk based dispensing variable value between 0 10000 0 set up standard value WARNING XXXX The machine will display the message manual milker cleaning when the programmed dispensing num...

Страница 38: ...le value between 0 infinite set up standard value 50 000 1 20 Coffee boiler temperature programming MACHINE PARAMETERS COFFEE TEMPERAT XX Y Where XX indicates the set up coffee boiler temperature and...

Страница 39: ...DRAIN TEMPERAT XX Y Where XX indicates the steam boiler temperature and Y indicates the unit in Centigrade or Fahrenheit variable value between 0 95 C 95 C set up standard value WARNING This function...

Страница 40: ...S H MOT DELIVERY POSIT IMPUL XXX In this parameter set the number of pulses which will stop the upper motor stroke when moving to dispensing position For instance if the maximum stroke is 575 pulses y...

Страница 41: ...e programming during automatic cleaning with detergent GROUP CLEANING PROG PAUSE XX s Where XX s indicates the pause time in seconds carried out by the coffee group cycle after inserting the detergent...

Страница 42: ...e the upper piston N 3 to move the lower piston Please Note this function allows to read the maximum strokes of the two pistons starting from stand by position move the lower and upper motors to their...

Страница 43: ...e previous programming environment and or exit The display shows TEST ACTUATORS Press the key activating the actuator that you wish to check See the key reference table Press the previously pressed ke...

Страница 44: ...ATION TOOLS TIME M1 XXXX h RESET INFORMATION SYSTEM DATA WATER FILTER LITRES XXXX L RESET INFORMATION TOTAL GROUP CYCLES XXXX L WARNING 1 The owner s card can only enter total dose reset environment a...

Страница 45: ...ORMATION MILKER CLEANING XXXX Where XXXX indicates the number of milker cleaning carried out Press the key N 16 3 4 5 X to display the next level the display shows RESET INFORMATION MILKER CLEANING CO...

Страница 46: ...ted by the water filter RESET INFORMATION WATER FILTER LITRES XXXX L Where XXX L indicates the total number of litres of the water filter Press the key N 16 3 4 5 X to display the next level the displ...

Страница 47: ...alarm number the machine can save is 10 b To reset the alarm data memory carry out preset machine procedure The alarms that will be saved in case of breakdown are the following 1 Upper group motor ala...

Страница 48: ...cards can be converted into smart cards having different functions except for the technician s smart card Descriptions of the system programming environment of the smart card 9 1 Device code display...

Страница 49: ...rmed the operation the display shows CARD CODE XXXXX Where the blinking X number indicates the second figure to be modified etc etc Repeat the above operations for all the other figures WARNING a If t...

Страница 50: ...he card inserted to enable the programming of waiter s card was the technician s OWNER if the card inserted to enable the programming of waiter s card was the owner s Insert the requested card the dis...

Страница 51: ...e technician or owner s card and insert the card to be programmed Once the card to be programmed has been inserted the display will automatically show the machine device code CARD CODE XXXXX Insert th...

Страница 52: ...the card inserted to enable the programming of the waiter s card was the technician s OWNER if the card inserted to enable the programming of the waiter s card was the owner s Insert the requested car...

Страница 53: ...been used in another device you must necessarily remember the card code previously programmed the operator has to remember the programmed code number of the card Without the card code the card cannot...

Страница 54: ...he code relevant to the card to be programmed the card code might be different from the device code To insert the card code proceed as follows The blinking X number indicates the first figure of the c...

Страница 55: ...waiter s card was the owner s Insert the requested card the display shows SYSTEM PROGRAMMING SMART CARD PROGRAMMING WARNING The value that can be inserted is determined by the difference between the m...

Страница 56: ...e of the code to be modified Press the key N 13 1x or N 14 2x to modify the figure Press the key N 16 3 4 5 X to confirm the modification Press the key N 15 gost2 to enter the next level without savin...

Страница 57: ...Only the technician s card can enter this programming level The display shows SYSTEM PROGRAMMING PRESET CONFIGURATION DATA Press the key N 16 3 4 5 X The display shows SYSTEM PROGRAMMING PLEASE CONFIR...

Страница 58: ...ded Four file numbers are available Press key 16 3 4 5 X to confirm the choice the display unit will display FILES MANAGER DOWNLOAD FROM FILE X REMOVE SMART CARD Remove the technical card the display...

Страница 59: ...nit will display FILES MANAGER LOAD ON FILE X REMOVE SMART CARD Remove the technical card the display unit displays FILES MANAGER LOAD ON FILE X INSERT CARDISK Insert the cardisk on which a new data c...

Страница 60: ...ARD In order to use the cyber card you need to transfer the software version onto it only with EEPROM at Mbyte 128 The software is transferred directly from a machine Daytona 1 or 2 Power with the cor...

Страница 61: ...CARD In order to upgrade the software in an Daytona1 or 2 Power machine proceed as follows The software can be upgraded in two ways 1 By the System Manager procedure 2 When switching on the machine 1...

Страница 62: ...ve the cyber card from the card reader PLEASE NOTE a The software upgrading operation must always end correctly so that the machine can work properly b If the procedure is interrupted by a drop in vol...

Страница 63: ...is stored in this parameter Only the technician s card can enter this programming level The display shows SYSTEM PROGRAMMING HISTORY HIGER MOTOR Press the key N 16 3 4 5 X to confirm the operation Pre...

Страница 64: ...machine in OFF mode and then turn it back on with the key N 11 ON OFF 3 Time out impulses lower piston motor MACHINE OFF NO H MOTOR IMP Causes the lower motor encoder has not received impulses for 3...

Страница 65: ...ric connections 12 Master card 13 Encoder card fault 14 Turn the machine in OFF mode and then turn it back on with the key N 11 ON OFF 7 Steam boiler filling alarm MACHINE OFF Cause the stage of boile...

Страница 66: ...Note If coffee is dispensed continuously use the machine as if it were manual press the desired key to start the dose then press the same key to stop the dose being dispensed after checking the amoun...

Страница 67: ...e reaches the working temperature b If the machine is in OFF mode the display shows OFF T O COFFEE HEATING It indicates that the heating up stage of the coffee boiler has exceeded 12 time out verify 1...

Страница 68: ...machine preset 8 Faulty control unit 9 Turn the machine in OFF mode and then turn it back on with the key N 11 ON OFF 16 Faulty data alarm MACHINE OFF FAULTY DATA Faulty data alarm can occur in two ca...

Страница 69: ...blem carry out machine preset 5 Faulty central unit WARNING To activate the safety thermostat it is necessary to press the button placed at the centre of the thermostat itself The thermostat is placed...

Страница 70: ...d time out is over Result the display shows the relevant icon without shutting down machine functioning Solution carry out manual group cleaning 23 Milker cleaning message with blocked deliveries In c...

Страница 71: ...in the rear lower part rotate it clockwise to increase the pressure and anti clockwise to decrease it The coffee dispensing pressure is displayed on the gauge placed on the boiler itself and can be s...

Страница 72: ...water mix flow adjustment for Tea The cold water mix solenoid valve adjustment screw must be adjusted as follows to change the amount of cold water that is mixed with the hot for making Tea open the m...

Страница 73: ...383033GB Pag 73 November 2003 BODY DISASSEMBLY PROCEDURE...

Страница 74: ...ay shows OFF It is absolutely necessary to cut off the machine voltage rating WARNING a If at the end of the boiler automatic draining procedure the machine voltage rating is not cut off when the mach...

Страница 75: ...crew RV2 move this trimmer to raise or lower the threshold for activating the lower piston motor start By turning clockwise the threshold is raised vice versa the threshold lowers Note that the adjust...

Страница 76: ...Steam boiler element relay RS Front door safety relay SLC Steam boiler level probe SLS Safety probe TS Thermostat STCV Steam boiler temper probe STCC Coffee boiler temper probe SLC Steam boiler level...

Страница 77: ...383033GB Pag 77 November 2003...

Страница 78: ...383033GB Pag 78 November 2003...

Страница 79: ...383033GB Pag 79 November 2003...

Страница 80: ...383033GB Pag 80 November 2003...

Страница 81: ...383033GB Pag 81 November 2003...

Страница 82: ...es due to printing and or typing errors contained in this publication All instructions drawings tables and information contained in this publication are reserved and may not be reproduced entirely or...

Отзывы: