10.3.3. Power Supply Error Code Table
Error
Code
F61 The abnormalities
In normal operation, when DCDET2
Press [ STOP] on
in an output or power
goes to "L" (Low) (Not during POWER
main unit for next error.
supply circuit of
OFF condition), F61 appears on FL
POWER AMP
Display and PCONT goes to "L" (Low).
This is due to speaker output has DC
voltage or fan is not working.
F76 Abnormality in the
In normal operation when DCDET1 is
Press [ STOP] on
output voltage of
detected "L" (Low) for two consecutive
main unit for next error.
stabilized power
times, F76 is displayed on FL for 2
supply
seconds and after that PCONT will be
turned to "L" (Low). This is due to any of
the DC voltages (+9V, +7V, -7V, +5V,
+5.3V etc.) not available.
H19
Abnormality in the
When the fan motor stops operating
Press [ STOP] on
fan operation
during power-up at normal operation.
main unit for next error.
After 1 seconds, the unit will
automatically shutdown to standby
mode after the error code appears on
the FL display.
U59
Abnormality in the
When there is a detection of
Press [ STOP] on
digital amp IC
abnormality to the digital amp IC at
main unit for next error.
time of normal operation. After 1
seconds, the unit will automatically
shutdown to standby mode after the
error code appears on the FL display.
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
10.3.4. ECC Error Code Table
Error
Code
F600 Administrative
It becomes impossible NaviPack etc.
Press [ STOP] on
information cannot
were done, and not to be able to
main unit for next error.
be acquired by the
acquire necessary information in the
recovery error.
navigation’s changing due to wound
etc. of DISC, and to have done the
reproduction transition.
F601 Irregular sector ID
It tried to access the position that did
Press [ STOP] on
was demanded.
not exist on DISC by the recording
main unit for next error.
error etc. of authoring.
F603 KEYDET cannot be The data for decoding copyright
Press [ STOP] on
acquired by the
protection (CSS) cannot be acquired
main unit for next error.
recovery error.
due to wound etc. of DISC, and it is not
possible to reproduce.
Diagnosis Contents
Description of error
Automatic FL Display
Remarks
60
SA-PTX7P
Summary of Contents for SA-PTX7P
Page 12: ...12 SA PTX7P ...
Page 29: ...RX RX RX RX CH2 AB CH2 AB CH1 CD B 1 1 1 Multi room Multi source 29 SA PTX7P ...
Page 66: ...11 2 Main Components and P C B Locations 66 SA PTX7P ...
Page 85: ...Step 3 Remove the middle chassis Step 4 Remove the traverse unit 85 SA PTX7P ...
Page 94: ...Note Insulate AC Inlet P C B from other parts with insulating material eg plastic 94 SA PTX7P ...
Page 97: ...97 SA PTX7P ...
Page 116: ...116 SA PTX7P ...
Page 118: ...SA PTX7P 118 ...
Page 130: ...SA PTX7P 130 ...
Page 132: ...132 SA PTX7P ...
Page 172: ...SA PTX7P 172 ...
Page 183: ...26 Exploded Views 183 SA PTX7P ...
Page 184: ...184 SA PTX7P ...
Page 185: ...26 1 Cabinet Parts Location SA PTX7P 185 ...
Page 186: ...SA PTX7P 186 ...
Page 187: ...SA PTX7P 187 ...
Page 188: ...SA PTX7P 188 ...
Page 189: ...26 2 Packaging SA PTX7P 189 ...