1
1-11-1-1-14
Others
Setting No.
(1)
Remote controller
setting data
Item code 5d
0001
Contents &
optional parts name
Air-flow blocking kit
(for 3-way air flow)*
2
1
High-ceiling setting 1*
2
(3)
0003
Air-flow blocking kit
(when a duct is
connected.)
(6)
High-ceiling setting 2*
2
0006
(1) Checking After Installation
1) Check that there are no gaps between the unit and the
panel for cassette, or between the panel for cassette
and the ceiling surface.
* Gaps may cause water leakage and condensation.
2) Check that the wiring is securely connected.
* If it is not securely connected, the auto flap will not
operate.
(“P09” is displayed on the remote controller.)
In addition, the water leakage and condensation may
occur.
(2) Operating the Wireless Remote Controller
For details of installation, refer to the section “Wireless
Signal Receiver” in the supplied installation instructions.
(3) Selecting DC Fan Motor Tap (4-Way Cassette)
Check the optional parts accordingly in the following
table.
Table for DC Fan Motor Tap Settings*
Air-flow blocking kit
(for 2-way air flow)*
2
*1 When using optional parts in different setting No. in
*2 Ceiling height (m)
combination with multiple units, conform it to the larger
setting No.
Indoor unit type
S-3650PU3E S-6071PU3E
Standard
2.7
3.0
(factory setting)
High-ceiling setting 1
3.2
3.3
High-ceiling setting 2
3.5
3.6
3.8
3.8
Air-flow blocking kit
(for 3-way air flow)
4.2
4.2
Air-flow blocking kit
(for 2-way air flow)
1) When setting on the indoor unit control PCB
<Procedure>
Stop the system before performing these steps.
1 Open the electrical component box cover, then
check the indoor unit control PCB.
2 Change the DIP switch (SW001) on the indoor unit
control PCB in accordance with the setting number
which was confirmed in “Table for DC Fan Motor
Tap Settings”.
Setting No.
DIP switch
Setting No.
DIP switch
(1)
TP6
TP3
TP1
ON
1 2 3
(6)
ON
TP6
1 2 3
TP3
TP1
(3)
ON
TP6
1 2 3
TP3
TP1
<Procedure of CZ-RTC5B>
Stop the system before performing these steps.
1 Keep pressing the
,
and
buttons
simultaneously for 4 or more seconds.
The “Maintenance func” screen appears on the LCD
display.
2 Press the
or
button to see each menu.
press the
button.
If you wish to see the next screen instantly, press the
or
button.
Select “8. Detailed settings” on the LCD display and
The “Detailed settings” screen appears on the LCD display.
TP6
TP3
TP1
1
ON
2 3
TP6
TP3
TP1
1 2 3
SW001
Indoor unit control PCB
Setting example
1: OFF
2: OFF
ON
3: ON
Maintenance func
Sel.
20:30 (THU)
Page [
] Confirm
1. Outdoor unit error data
2. Service contact
3. RC setting mode
4. Test run
Maintenance func
Sel.
20:30 (THU)
Page [
] Confirm
5. Sensor info.
6. Servicing check
7. Simple settings
8. Detailed settings
SM830283-00_欧州向け R32シングル36-71形TD&SM.indb 14
20/01/30 10:25:11
Summary of Contents for S-3650PF3E
Page 20: ...19 MEMO SM830283 00_欧州向け R32シングル36 71形TD SM indb 19 2020 01 29 21 46 03 ...
Page 178: ... MEMO 1 13 5 SM830283 00_欧州向け R32シングル36 71形TD SM indb 5 20 01 30 10 26 09 ...
Page 198: ... MEMO 2 4 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 19 52 20 ...
Page 204: ... MEMO 3 2 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 20 01 28 11 25 46 ...
Page 270: ... MEMO 5 4 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 21 17 57 ...
Page 272: ... MEMO 6 1 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 20 10 15 08 ...
Page 294: ... MEMO 7 21 SM830283 00_欧州向け R32シングル36 71形TD SM indb 21 20 01 28 11 22 25 ...
Page 321: ...202001 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 23 9 32 11 ...