4-13
4 4
4-12-7. Compressor Overheating Prevention Control
Instructed frequency for compressor operation will be regulated by compressor temperature. The changes of
frequency are as below.
If compressor temperature exceeds 103°C, compressor will be stopped.
Compressor = OFF
Compressor Frequency
Reduce
Compressor Frequency
Limited
Free
103°C
99°C
96°C
Comp. temperature
88°C
87°C
86°C
4-12-8. Deice Operation
When outdoor pipe temperature and outdoor air tempertature is low, deice operation start where indoor fan motor
and outdoor fan motor stop.
4-12-6. Cooling Freeze Prevention Control
The following control is performed during cooling operations (including dry mode operation), in accordance
with whichever of the indoor heat exchanger temperatures (E1 or E2) is lower. (See the chart below.)
(a) Frequency will not be decreased less than 5.5 minutes after thermostat ON.
(b) The threshold value is increased in accordance with the indoor load (differences of temperature).
min(E1, E2)
11°C
≥
<
9°C
10°C
≥
<
7°C
9°C
≥
<
5°C
6°C
≥
<
0°C
Free
Frequency reduce
Frequency limited
Compressor stop in 360 seconds
Frequency maintain
SM830283-00_欧州向け R32シングル36-71形TD&SM.indb 13
2020/01/30 13:58:47
Summary of Contents for S-3650PF3E
Page 20: ...19 MEMO SM830283 00_欧州向け R32シングル36 71形TD SM indb 19 2020 01 29 21 46 03 ...
Page 178: ... MEMO 1 13 5 SM830283 00_欧州向け R32シングル36 71形TD SM indb 5 20 01 30 10 26 09 ...
Page 198: ... MEMO 2 4 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 19 52 20 ...
Page 204: ... MEMO 3 2 1 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 20 01 28 11 25 46 ...
Page 270: ... MEMO 5 4 3 SM830283 00_欧州向け R32シングル36 71形TD SM indb 3 2020 01 29 21 17 57 ...
Page 272: ... MEMO 6 1 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 20 10 15 08 ...
Page 294: ... MEMO 7 21 SM830283 00_欧州向け R32シングル36 71形TD SM indb 21 20 01 28 11 22 25 ...
Page 321: ...202001 SM830283 00_欧州向け R32シングル36 71形TD SM indb 1 20 01 23 9 32 11 ...