Names of Parts 

INDOOR UNIT

OUTDOOR UNIT

 

Water drain

Ceiling panel 

(optional)

Air outlet

(4 locations)

Air intake grille

(air intake)

Label

(attached to the lid of electrical component box)

This air conditioner incorporates a biocidal product.

Ionized air generated by a device incorporated 
in the air conditioner deactivates bacteria and
viruses in the air, and on surfaces, and inhibits 
mould growth on surfaces.
Active substances: free radicals generated in situ
                                from ambient air or water

 

„

Operation & Adjusting Airfl ow Direction

Refer to the Operating Instructions attached to the Remote Controller.

* The fl ap display on the remote controller differs from the actual fl ap angle.

A

Model No.

CZ-RTC4

For all indoor  

units

Read the Operating Instructions included with the Remote Controller. 

Wireless Remote 

Controller

Timer Remote 

Controller

Wired Remote 

Controller

High-spec Wired 

Remote Controller

Optional

mini VRF (Type LZ2)

mini VRF (Type LE1, LE2)

2WAY VRF (Type ME2)

3WAY VRF (Type MF3)

NOTE

Refer to the Operating Instructions attached to the 

outdoor unit.

4, 5, 6 HP

Air intake (rear, left side)

Air outlet

Anchor hole

Drain port (bottom)

8,10 HP

Model No. CZ-RWS3

The receiver : Model No.

CZ-RWRU3* (Type U2)

CZ-RWRC3

(For all indoor units)

(Infrared Remote Controller)

Model No.

CZ-RTC5B

For all indoor 

units

Model No.

CZ-RTC6*

For all indoor  

units

01_330422_EN.indb   7

2021/3/8   9:16:39

Summary of Contents for S-22MU2E5B

Page 1: ...2E5B S 90MU2E5B S 36MU2E5B S 106MU2E5B S 45MU2E5B S 140MU2E5B S 56MU2E5B S 160MU2E5B S 60MU2E5B Connectable outdoor unit lineup OUTDOOR UNIT Refrigerant type R410A mini VRF Type LE1 LE2 2WAY VRF Type...

Page 2: ...se as described in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product d...

Page 3: ...oles must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint c...

Page 4: ...detect the refrigerant leakage when the refrigerant leaks and it may lead to cause the generation of toxic gas and fire Do not use the following items near the indoor unit and R32 refrigerant leakage...

Page 5: ...ning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision D...

Page 6: ...recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC By...

Page 7: ...te Controller The flap display on the remote controller differs from the actual flap angle A Model No CZ RTC4 For all indoor units Read the Operating Instructions included with the Remote Controller W...

Page 8: ...ration automatically Operation settings prior to power failure will be used WARNING z z For safety be sure to turn the air conditioner off and disconnect the power before cleaning Otherwise electric s...

Page 9: ...opagations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptab...

Page 10: ...ntrol display shows at right NOTES z z Internal cleaning function is not possible to use any remote controller other than that of nanoe X function z z When connected to the remote controller which is...

Page 11: ...nt leakage detection sensor is connected and the refrigerant leaks P08 alarm and inspection mark will be displayed on the remote controller and the fan will automatically operate Please ventilate the...

Page 12: ...does not stop even when you press ON OFF operation button on remote controller R32 refrigerant leakage detection sensor connected to the indoor unit has detected refrigerant leakage In such a case do...

Page 13: ...8 ME2 3 phase U 8ME2E8 U 10ME2E8 MF3 3 phase U 8MF3E8 U 10MF3E8 Outdoor unit type 12 HP 14 HP 16 HP 18 HP 20 HP ME2 3 phase U 12ME2E8 U 14ME2E8 U 16ME2E8 U 18ME2E8 U 20ME2E8 MF3 3 phase U 12MF3E8 U 14...

Page 14: ...ns H W D mm 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 Net weight kg 24 24 24 24 24 25 Model Name S 73MU2E5B S 90MU2E5B S 106MU2E5B S 140MU2E5B S 160MU2E5B Pow...

Page 15: ...6 C 30 C DB In the case of nanoe X OFF Values include the dimensions and weight of an optional ceiling panel Fan speed display on the remote controller High CZ RTC4 CZ RTC5B CZ RTC6 Medium CZ RTC4 CZ...

Page 16: ...8 U 6LZ2E8 Power source 380 400 415 V 3N 50 Hz Cooling capacity kW 12 1 14 0 15 5 Heating capacity kW 12 5 16 0 16 5 Sound pressure level Cooling Heating dB A 52 54 53 56 54 56 Sound power level Cooli...

Page 17: ...0 1 500 980 370 Net weight kg 132 133 Operation condition temperature range Cooling mode 10 C 52 C DB Heating mode 20 C 18 C WB Rated conditions Cooling Indoor intake air temp 27 C DB 19 C WB Outdoor...

Page 18: ...e the Panasonic website for further information on collection centers etc or call the customer care toll free number http www panasonic com in corporate sustainability panasonic india i recycle progra...

Reviews: