Operation Mechanism

 

„

Heating performance

z

z

This air conditioner utilizes outside air for heating; its 

heating performance reduces as outside temperature 

decreases.

 

→ In the event that heating is not sufficient, please use an 

additional heating appliance.

 

„

Defrosting

z

z

This appliance may start defrosting operation to melt 

frost formed in the outdoor unit.

 

Defrosting starts

: The indoor unit fan stops (or the 

speed becomes extremely slow).

 

→ “ ” (STANDBY) appears.

 

Heating operation resumes after several 

minutes

: The indoor unit fan remains stopped (or 

it will run at a very slow speed) until the indoor heat 

exchanger coil warms up sufficiently.

 

→ “ ” (STANDBY) appears.

 

Defrosting is complete

: The indoor unit fan starts 

operation.

 

→ “ ” (STANDBY) disappears.

 

„

‘‘DRY’’ operation

z

z

Once the room temperature reaches the level that was 

set, the outdoor unit repeats the cycle of turning on and 

off automatically.

z

z

When the room temperature is more likely to reach the 

level that was set, the fan speed is set to ‘‘breeze’’ (light 

wind) automatically.

 

„

Should power failure occur while the unit is 

running

The unit will resume operation automatically. Operation 

settings prior to power failure will be used.

WARNING

z

z

For safety, be sure to turn the air conditioner off and disconnect 

the power before cleaning. (Otherwise, electric shock or injury may 

result because the fan is rotating at high speed.)

z

z

Do not pour water on the indoor unit. (This may damage the internal 

components and cause an electric shock hazard.)

CAUTION

z

z

Never use solvents or harsh chemicals. Also, do not wipe plastic 

parts using very hot water. (This may cause deformation or change 

in colour.)

z

z

Some metal edges and fins are sharp. Be careful when you clean 

those parts. (Injury may result.)

z

z

Use a firm stool or ladder when cleaning an indoor unit installed in 

high locations.

Maintenance 

„

 Indoor unit

 (e.g. Type U2)

„

 The internal coil and other components of the 

outdoor unit must be cleaned periodically.

• Consult your dealer or service center.

 

„

Air Filter Maintenance

Consult your dealer or service center when the 

 

(Filter) appears on the display of the wired remote controller.

Air outlet

Air intake

Wipe with a soft cloth.

(If it is very dirty, use a cloth moistened with 

water.)

Timer Remote Controller

High-spec Wired 

 

Remote Controller

Filter indicator

A

°

Filter indicator

Wired Remote Controller

Filter indicator

01_330422_EN.indb   8

2021/3/8   9:16:39

Summary of Contents for S-22MU2E5B

Page 1: ...2E5B S 90MU2E5B S 36MU2E5B S 106MU2E5B S 45MU2E5B S 140MU2E5B S 56MU2E5B S 160MU2E5B S 60MU2E5B Connectable outdoor unit lineup OUTDOOR UNIT Refrigerant type R410A mini VRF Type LE1 LE2 2WAY VRF Type...

Page 2: ...se as described in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product d...

Page 3: ...oles must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint c...

Page 4: ...detect the refrigerant leakage when the refrigerant leaks and it may lead to cause the generation of toxic gas and fire Do not use the following items near the indoor unit and R32 refrigerant leakage...

Page 5: ...ning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision D...

Page 6: ...recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC By...

Page 7: ...te Controller The flap display on the remote controller differs from the actual flap angle A Model No CZ RTC4 For all indoor units Read the Operating Instructions included with the Remote Controller W...

Page 8: ...ration automatically Operation settings prior to power failure will be used WARNING z z For safety be sure to turn the air conditioner off and disconnect the power before cleaning Otherwise electric s...

Page 9: ...opagations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptab...

Page 10: ...ntrol display shows at right NOTES z z Internal cleaning function is not possible to use any remote controller other than that of nanoe X function z z When connected to the remote controller which is...

Page 11: ...nt leakage detection sensor is connected and the refrigerant leaks P08 alarm and inspection mark will be displayed on the remote controller and the fan will automatically operate Please ventilate the...

Page 12: ...does not stop even when you press ON OFF operation button on remote controller R32 refrigerant leakage detection sensor connected to the indoor unit has detected refrigerant leakage In such a case do...

Page 13: ...8 ME2 3 phase U 8ME2E8 U 10ME2E8 MF3 3 phase U 8MF3E8 U 10MF3E8 Outdoor unit type 12 HP 14 HP 16 HP 18 HP 20 HP ME2 3 phase U 12ME2E8 U 14ME2E8 U 16ME2E8 U 18ME2E8 U 20ME2E8 MF3 3 phase U 12MF3E8 U 14...

Page 14: ...ns H W D mm 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 Net weight kg 24 24 24 24 24 25 Model Name S 73MU2E5B S 90MU2E5B S 106MU2E5B S 140MU2E5B S 160MU2E5B Pow...

Page 15: ...6 C 30 C DB In the case of nanoe X OFF Values include the dimensions and weight of an optional ceiling panel Fan speed display on the remote controller High CZ RTC4 CZ RTC5B CZ RTC6 Medium CZ RTC4 CZ...

Page 16: ...8 U 6LZ2E8 Power source 380 400 415 V 3N 50 Hz Cooling capacity kW 12 1 14 0 15 5 Heating capacity kW 12 5 16 0 16 5 Sound pressure level Cooling Heating dB A 52 54 53 56 54 56 Sound power level Cooli...

Page 17: ...0 1 500 980 370 Net weight kg 132 133 Operation condition temperature range Cooling mode 10 C 52 C DB Heating mode 20 C 18 C WB Rated conditions Cooling Indoor intake air temp 27 C DB 19 C WB Outdoor...

Page 18: ...e the Panasonic website for further information on collection centers etc or call the customer care toll free number http www panasonic com in corporate sustainability panasonic india i recycle progra...

Reviews: