1. Contents of Remote Controller
Switch Alarm Display
2WAY SYSTEM
Trouble Diagnosis
6
ON:
Blinking:
OFF:
Possible cause of malfunction
Wired
remote
control
display
Wireless
remote controller
receiver display
Operation
Timer
Standby
for heating
Serial
communication
errors
Mis-setting
Remote controller is detecting
error signal from indoor unit.
Error in receiving serial communication signal. (Signal from
main indoor unit in case of group control) Outdoor system
address, indoor unit address, or indoor unit address
independent/main/sub unit setting has not been made.
(Auto address is not completed.)
<E01>
Error in transmitting serial communication signal.
<E02>
Indoor unit is detecting error signal from remote controller and system controller.
<<E03>>
Indoor unit is detecting error
signal from outdoor unit.
Error in receiving serial communication signal.
When turning on the power supply, the number of
connected indoor units does not correspond to the number
set. (Except R.C. address is “0.”)
Group wiring failure of indoor units in the refrigerant system
(occurring when remote controller is operated immediately
after automatic address setting)
•
•
•
E04
Outdoor unit is detecting error
signal from indoor unit.
Error in receiving serial communication signal.
There is an indoor unit which does not send signals when
the power is ON.
•
6
0
E
•
Indoor unit address setting is duplicated.
>
>
8
0
E
<
<
•
Duplicated remote controller “main” setting.
>
>
9
0
E
<
<
•
Automatic address setting start is prohibited.
AP pin was short-circuited at time when automatic address
setting was started.
E12
Indoor unit communication
error of group control wiring.
Error of main indoor unit in receiving serial communication
signal from sub indoor units.
E18
During auto. address setting,
number of connected units
does not correspond to
number set.
Improper setting
Improper setting
Improper setting
Indoor unit
Number of connected indoor units is less than the number set.
Number of connected indoor units is more than the number set.
E16
E20
E15
No indoor unit is connected during auto. address setting.
Main outdoor unit is detecting error signal from sub outdoor unit.
E24
5
2
E
Duplicated outdoor unit address.
6
2
E
Mismatch in “No. of outdoor units” setting.
Error of sub outdoor unit in receiving serial communication
signal from main outdoor unit.
E29
E30
E31
Outdoor unit serial communications failure.
Communication error between the microcomputers
>
>
2
0
L
<
<
Connected indoor unit is not a multi unit.
Duplication of main indoor unit address setting in group control.
<L03>
Duplicated indoor unit priority (priority indoor unit).
Duplicated indoor unit priority (non-priority indoor unit) and
outdoor unit.
L06
L05
8
0
L
Indoor unit address is not set.
>
>
9
0
L
<
<
Capacity code of indoor unit is not set.
Mismatch of outdoor unit type.
4-way valve operation failure
Duplication of outdoor R.C. address setting.
L04
L17
L18
Capacity code of outdoor unit is not set.
L10
Group control wiring is connected to individual control indoor unit.
L07
Thermistor
fault
>
>
1
0
F
<
<
Indoor coil temp. sensor (E1)
>
>
3
0
F
<
<
Indoor coil temp. sensor (E3)
>
>
0
1
F
<
<
>
>
1
1
F
<
<
Indoor discharge air temp. sensor
Indoor suction air (room) temp. sensor
Continued
Operating lamp
blinking
Heating ready lamp
blinking
Operating lamp
blinking
Heating ready lamp
blinking
Operating and heating
ready lamps blinking
simultaneously
Operating and heating
ready lamps blinking
simultaneously
Operating and
timer lamps blinking
alternately