1-1
EARTH GROUND
1500
Ω
. 10W
0.15
µ
F
AC VOLTMETER
Hot-Check Circuit
TO
APPLIANCES
EXPOSED
METAL PARTS
GENERAL GUIDELINES
1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essential
that these critical parts should be replaced with
manufacturer's specified parts to prevent X-RADIATION,
shock, fire, or other hazards. Do not modify the original
design without permission of manufacturer.
2. An Isolation Transformer should always be used during the
servicing of Combination VCR whose chassis is not iso-
lated from the AC power line. Use a transformer of ad-
equate power rating as this protects the technician from
accidents resulting in personal injury from electrical shocks.
It will also protect Combination VCR from being damaged
by accidental shorting that may occur during servicing.
3. When servicing, observe the original lead dress, especially
the lead dress in the high voltage circuits. If a short circuit
is found, replace all parts which have been overheated or
damaged by the short circuit.
4. After servicing, see to it that all the protective devices such
as insulation barriers, insulation papers, shield, and isola-
tion R-C combinations are properly installed.
5. Before turning the receiver on, measure the resistance
between B+ line and chassis ground. Connect (-) side of an
ohmmeter to the B+ lines, and (+) side to chassis ground.
Each line should have more resistance than specified, as
follows :
B+ Line
Minimum Resistance
130V
1K ohm
(Hot chassis ground)
27V
180 ohms
(Cold chassis ground)
17V
110 ohms
(Cold chassis ground)
6. When the TV set is not used for a long period of time,
unplug the power cord from the AC outlet.
7. Potentials, as high as 32.0KV are present when this TV set
is in operation. Operation of the TV set without the rear
cover involves the danger of a shock hazard from the TV
set power supply. Servicing should not be attempted by
anyone who is not thoroughly familiar with the precautions
necessary when working on high voltage equipment. Al-
ways discharge the anode of the picture tube to the CRT
ground of receiver before handling the tube.
8. After servicing make the following leakage current checks
to prevent the customer from being exposed to shock
hazards.
LEAKAGE CURRENT COLD CHECK
1. Unplug the AC cord and connect a jumper between the two
prongs on the plug.
2. For physically operated power switches, turn power on.
Otherwise skip step 2.
3. Measure the resistance value, with an ohmmeter, between
the jumpered AC plug and each exposed metallic cabinet
part on the receiver, such as screwheads, connectors, etc.
When the exposed metallic part has a return path to the
chassis, the reading should be between 1 M ohm and 12
M ohms. When the exposed metal does not have a return
path to the chassis, the reading must be infinity.
LEAKAGE CURRENT HOT CHECK
1. Plug the AC cord directly into the AC outlet.
Do not use a isolation transformer for this check.
2. Connect a 1.5K ohms, 10 watts resistor, in parallel with a
0.15 micro farad capacitor, between each exposed metal-
lic part on the set and a good earth ground , as shown in
Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensi-
tivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt-
age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the
above measurements.
6. The potential at any point should not exceed 0.75 volt RMS.
A leakage current tester (Simpson Model 229 equivalent)
may be used to make the hot checks. Leakage current
must not exceed 1/2 milliampere. In case a measurement
is outside of the limits specified, there is a possibility of
shock hazard, and the receiver should be repaired and
rechecked before it is returned to the customer.
Figure 1
X-RADIATION
WARNING :
1. The potential source of X-Radiation in TV sets is the High
Voltage section and the picture tube.
2. When using a picture tube test fixture for service, ensure
that the fixture is capable of handling 32.0KV without
causing X-Radiation.
NOTE :
It is important to use an accurate periodically calibrated
high voltage meter.
1. Reduce the brightness to minimum.
2. Set the SERVICE switch to SERVICE .
3. Measure the High Voltage. The meter reading should indi-
cate 30.0 +/- 2.0KV .
If the meter indication is out of tolerance, immediate service
and correction is required to prevent the possibility of
premature component failure.
4. To prevent an X-Radiation possibly, it is essential to use the
specified picture tube.
SAFETY PRECAUTIONS
Summary of Contents for PV-M2738 Operating
Page 56: ......
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......
Page 94: ......
Page 95: ......
Page 96: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 101: ......
Page 102: ......
Page 103: ......
Page 104: ......
Page 105: ......
Page 106: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 120: ......
Page 121: ......
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......
Page 127: ......
Page 128: ......
Page 151: ...Printed in Japan...