3-18
4. Getting Start
1. Confirm SW setting of the Interface Board as follows.
Set SW104(BST_TEST) to [NORMAL].
Set SW106(REC_I) to [OFF].
2. Turn on the Personal Computer.
3. Main menu appears.
4. Start up the PC-EVR Adjustment Program refer to “SET UP OF PC-EVR ADJUSTMENT PROGRAM” and select “Enter TEST
MODE” in “Enter/Release TEST MODE” menu, and enter the TEST MODE.
NOTE:
After LISTA adjustment is completed, select “Release TEST MODE” in “Enter/Release TEST MODE” menu, and release the
TEST MODE.
5. Turn Satellite Box, MIC Reader and ATF I/F on.
6. Apply DC 6V to the Interface Board.
7. Set the Power Switch to VCR mode, and the Camcorder is powered on.
8. Insert the Linear Alignment Tape.
Linearity monitor system of track
using ATF error signal for DVC
Ver 1.02 1996.12.9 T.U PK3 ALL
MANU
(MAIN MENU)
9. Press ENTER. The program is run and the Linear Alignment Tape is played back automatically.
“AVE. 10” display appears as follows.
10. Confirm the indicator color in the Confirmation Area.
If it is blue, the adjustment is not required and go to step 11 to exit from this menu. If it is red, the adjustment is
necessary. Perform “6. Envelope Adjustment”.
-6
-4
-2
0
2
4
6
10
174
[F1] AVE. 10
[F2] AVE. 3
[F3] AVERAGE
[F4] SENSI.
[F5] PGMM ADJ
[F6] MIC READ
[F7] MIC ZERO
[F8] MIC DATA
[F9] SAVE
[F10] MENU
Play Stop Ff Rew Eject
LINEAR= m
SENSIVITY : 269.886
DIFFERENCE : 16.358
MIC : 50911004
LIM : 3.00
MINI : 1.72
MAX : 3.65
AVE : 2.33
AVE : 10
GAIN : 50
Indicator
Confirmation Area
(AVE.10 display)
11. After confirmation and adjustment is completed, press F10 (Main Menu appears).
Then select (0) on Main Menu to return to MS-DOS.
Summary of Contents for PV-DAC10
Page 38: ...2 24 Dumper Unit Fig DM6 6 Dumper Unit S 4 ...
Page 52: ...2 38 Loading Motor Unit Fig DM20 26 Loading Motor Unit S 11 chassis holes Bosses ...
Page 58: ...2 44 MIC Switch Fig DM26 34 MIC Switch S 15 Bosses chassis holes ...
Page 60: ...2 46 T4 Drive Arm Fig DM28 36 T4 Drive Arm ...
Page 195: ...Printed in Japan ...