![Panasonic PV-DAC10 Service Manual Download Page 44](http://html.mh-extra.com/html/panasonic/pv-dac10/pv-dac10_service-manual_256374044.webp)
2-30
Tension Arm Unit
Fig. DM12
Reassembly Notes:
1. Installation of Tension Arm Unit
1) Before installing the Tension Arm Unit, place the
Mechanism in STOP Position by rotating the Mode
Switch, (Confirm that the S Connection Gear Unit is
separated from S Reel Gear.) and then hook the Spring
of Tension Arm Unit to Hooking Portion A and Hooking
Portion B.
2) Install the Tension Arm Unit while hooking the Band of
Tension Unit to groove of S Reel Table.
3) Confirm that Band of Tension Arm Unit and Projection
on Sensor F.P.C. are in the correct position, and that
Cam follower Pin is set into Slot of Tension Arm Unit.
4) After installing the Tension Arm Unit, unhook the Spring
from Portion A, and then confirm that the Spring is in the
lower position than Sensor F.P.C.
Disassembly Notes:
1. Work carefully so as not to damage the Band of Tension
Arm Unit when removing.
13 Tension Arm Unit
(C-3)
Spring
Projection on
Sensor F.P.C.
Projection on
Sensor F.P.C.
Hooking
Portion A
Hooking
Portion B
groove of S Reel Table
Band of Tension Arm Unit
Cam Follower Pin
S Connection Gear Unit
S Reel Table
approx. 1 mm
Cam Follower Pin
Slot
Summary of Contents for PV-DAC10
Page 38: ...2 24 Dumper Unit Fig DM6 6 Dumper Unit S 4 ...
Page 52: ...2 38 Loading Motor Unit Fig DM20 26 Loading Motor Unit S 11 chassis holes Bosses ...
Page 58: ...2 44 MIC Switch Fig DM26 34 MIC Switch S 15 Bosses chassis holes ...
Page 60: ...2 46 T4 Drive Arm Fig DM28 36 T4 Drive Arm ...
Page 195: ...Printed in Japan ...