6. Troubleshooting
6. 1. Summary of shut down system
Value "**" is changed by "Lamp mode", or "Fan mode" and "Setting attitude"
-
Connection problem with Intake air
temperature sensor.
Faulty temperature sensor.
-
-
-
-
Lamp unit cover is not installed.
Blown out of the fuse
(with some reason)
Iris unit abnormal
Iris drive circuit abnormal
Communication line is disconnection
in A-P.C.Board.
Connector is disconnected
Fan abnormal
Fan speed abnormal
Over 3800 hours
=> “Replace lamp"
Lamp hours
=> Over 4000 hours
(Shouts down after 10
minutes.)
Intake air temperature error
High temperature of environment
Intake air window is closed
Exhausting air temperature error:
Closed ventilator
High altitude mode is not on.
Lamp usage hour is over the guideline.
Lamp status
=> Lamp is off during the status
other than normal one
Intake air temperature sensor:
=> More than 43 degrees C
"Air filter cleaning"
When the abnormality of the lamp and the abnormality of the fan occurred, possess a shut down function to make a
standby state for safety promptly.
Monitor LED indication
OSD Warning Indication
-
Presumed Factor
Blown out of the fuse
(with some reason)
Power fuse
=> 8A 250V
Shut down Detection
LAMP LED Lights
Intake air temperature sensor:
=> Under -36 degrees C
Exhaust air temperature
sensor:
=> More than 79 degrees C
Filter air temperature
sensor:
=> More than threshold
** degrees C
Exhaust air temperature
sensor:
=> Under -36 degrees C
LAMP indicator
Flashing red
TEMP indicator
Flashing red
No FAN sense signal
Each FAN sense signal:
=> Rotation speed is slower
than 50% of target for
more than 10 seconds.
-
All indicator Illuminating
Interlock SW
=> Abnormal :OFF
No flashing or blinking
-
Thermal fuse
=> More than 105 degrees C
IRIS sense signal
=> Unresponsiveness is more
than 1 minute
IIC bus
=>FPGA initialized error
=>Communication error
-
Failed lamp ON,
lamp abnormal condition
Ballast block faulty,
Hot restart
-
Connection problem with Exhausting air
temperature sensor.
Faulty temperature sensor.
Filter clogging
Closed Intake
High altitude mode is not on
More than 41 degrees C
=>“TEMPERATURE WARNING"
lower than 39 degrees C
=> Warring cancel
More than 77 degrees C
=>“TEMPERATURE WARNING"
lower than 75 degrees C
=> Warring cancel
INF - 15
Summary of Contents for PT_AT6000E
Page 8: ...1 Name and function 1 1 Projector body Top and front view Back and bottom view INF 2 ...
Page 9: ...1 2 Control Panel 1 3 Rear terminals 1 4 Remote control INF 3 ...
Page 11: ... MENU MENU 2 2 Note The default settings may be different depending on the picture menu INF 5 ...
Page 16: ...4 7 Inquiry commands Refer to Operating Instructions of PT AE8000 PT AT6000 INF 10 ...
Page 75: ......