Chapter 4
Settings — [NETWORK] menu
186 - ENGLISH
[NETWORK] menu
On the menu screen, select [NETWORK] from the main menu, and select an item from the sub-menu.
Refer to “Navigating through the menu” (
x
page 86) for the operation of the menu screen.
[DIGITAL LINK]
Perform the setting and operation regarding the DIGITAL LINK.
[DIGITAL LINK MODE]
Switch the communication method of the <DIGITAL LINK/LAN> terminal of the projector.
1) Press
as
to select [DIGITAL LINK].
2) Press the <ENTER> button.
f
The
[DIGITAL LINK]
screen is displayed.
3) Press
as
to select [DIGITAL LINK MODE].
4) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[AUTO]
Switches the communication method automatically to DIGITAL LINK, long reach, or Ethernet.
[DIGITAL LINK]
Fixes the communication method to DIGITAL LINK.
[LONG REACH]
Fixes the communication method to long reach.
[ETHERNET]
Fixes the communication method to Ethernet.
r
Possible communication modes
l
: Communication possible
―: Communication not possible
Setting
Communication possible
Video transfer
(100 m (328'1"))
Video transfer
(150 m (492'2"))
Ethernet
RS-232C
[AUTO]
For DIGITAL LINK
l
―
l
l
For long reach
―
l
l
l
For Ethernet
―
―
l
*1
―
[DIGITAL LINK]
l
―
l
l
[LONG REACH]
―
l
l
l
[ETHERNET]
―
―
l
*1
―
*1 Communication via a twisted-pair-cable transmitter is not available. Connect the projector to the network directly.
Note
f
For the signal with resolution of 1 920 x 1 200 dots or less, the maximum transmission distance is 100 m (328'1") when connected with the
DIGITAL LINK communication method.
f
For the signal with the resolution exceeding 1 920 x 1 200 dots, the maximum transmission distance is 50 m (164'1").
f
The maximum transmission distance when connected with the long‑reach communication method is 150 m (492'2"). In this case, the signal
that the projector can receive is only up to 1080/60p (1 920 x 1 080 dots, dot clock frequency 148.5 MHz).
f
When the communication method of the twist-pair-cable transmitter is set to long reach, the projector will connect with long-reach
communication method when [DIGITAL LINK MODE] is set to [AUTO]. To connect with the optional DIGITAL LINK Switcher (Model No.:
ET-YFB200G) with the long-reach communication method, set [DIGITAL LINK MODE] to [LONG REACH].
f
Connection will not be made correctly if the twist-pair-cable transmitter is not supporting the long-reach communication method even if
[DIGITAL LINK MODE] is set to [LONG REACH].
[DIGITAL LINK STATUS]
Display the DIGITAL LINK connection environment.
1) Press
as
to select [DIGITAL LINK].
2) Press the <ENTER> button.
f
The
[DIGITAL LINK]
screen is displayed.
3) Press
as
to select [DIGITAL LINK STATUS].