Chapter 5
Operations — Web control function
210 - ENGLISH
[E-mail set up] page
Send an E‑mail to preset E‑mail addresses (up to two addresses) when a problem has occurred.
Click [Detailed set up]
→
[E-mail set up].
1
2
3
4
5
6
1 [ENABLE]
Select [ENABLE] to use the E-mail function.
2 [SMTP SERVER NAME]
Enter the IP address or the server name of the E-mail server
(SMTP). To enter the server name, the DNS server needs to be
set up.
3 [MAIL FROM]
Enter the E‑mail address of the projector. (Up to 63 characters
in single byte)
4 [MEMO]
Enter information such as the location of the projector that
notifies the sender of the E‑mail. (Up to 63 characters in single
byte)
5 [MINIMUM TIME]
Change the minimum interval for the temperature warning
E-mail. The default value is 60 minutes. In this case, another
E-mail will not be sent for 60 minutes after sending the
temperature warning E-mail even if it reaches the warning
temperature.
6 [INTAKE AIR TEMPERATURE]
Change the temperature setting for the temperature warning
mail. A temperature warning E-mail is sent when the
temperature exceeds this value.
8
7
9
8
7
7 [E-MAIL ADDRESS 1], [E-MAIL ADDRESS 2]
Enter the E-mail address to be sent. Leave [E-MAIL ADDRESS
2] blank when two E-mail addresses are not to be used.
8 Settings of the conditions to send E-mail
Select the conditions to send E-mail.
[MAIL CONTENTS]:
Select either [NORMAL] or [SIMPLE].
[ERROR]:
Send an E-mail when an error occurred in the self-diagnosis.
[INTAKE AIR TEMPERATURE]:
Send an E-mail when the intake air temperature has reached
the value set at the above field.
[PERIODIC REPORT]:
Place a check mark on this to send an E-mail periodically.
An E-mail will be sent on the day and time with the check mark.
9 [Submit]
Updates the settings and sends the details by E-mail.