Chapter 4
Settings — [PROJECTOR SETUP] menu
144 - ENGLISH
2) Press
qw
to switch the item.
f
The items will switch each time you press the button.
[OFF]
Disables the AC voltage monitor function.
[ON]
Enables the AC voltage monitor function.
Note
f
When [ON] is set, the value of the input supply voltage is always displayed in the self-diagnosis display while the main power of the projector
is turned on.
f
Even when [OFF] is set, the value of input supply voltage can be displayed temporarily in the self-diagnosis display by operating the button
on the remote control. (
x
page 74)
f
The value of input supply voltage cannot be displayed in the self-diagnosis display during standby when the [PROJECTOR SETUP] menu
→
[STANDBY MODE] (
x
page 134) is set to [ECO].
[SAVE ALL USER DATA]
Save the various setting values as a backup in the built-in memory of the projector.
1) Press
as
to select [SAVE ALL USER DATA].
2) Press the <ENTER> button.
f
The
[SECURITY PASSWORD]
screen is displayed.
3) Enter a security password and press the <ENTER> button.
4)
When the confirmation screen is displayed, press
qw
to select [OK], and press the <ENTER> button.
f
[PROGRESS] is displayed while saving data.
Note
f
Data set from the computer application is not included in [ALL USER DATA].
[LOAD ALL USER DATA]
Load the various setting values saved as a backup in the built-in memory of the projector.
1) Press
as
to select [LOAD ALL USER DATA].
2) Press the <ENTER> button.
f
The
[SECURITY PASSWORD]
screen is displayed.
3) Enter a security password and press the <ENTER> button.
4)
When the confirmation screen is displayed, press
qw
to select [OK], and press the <ENTER> button.
Note
f
The projector enters the standby mode to reflect the setting values when [LOAD ALL USER DATA] is executed.
f
Data registered from a computer is not included in [ALL USER DATA].
[INITIALIZE]
Return various setting values to their factory default settings.
1) Press
as
to select [INITIALIZE].
2) Press the <ENTER> button.
f
The
[SECURITY PASSWORD]
screen is displayed.
3) Enter a security password and press the <ENTER> button.
f
The
[INITIALIZE]
screen is displayed.
4) Press
as
to select an item to initialize.
[ALL USER DATA]
Returns all setting values including [REGISTERED SIGNAL], [NETWORK SETUP], [E-mail set up],
and [USER LOGO] to the factory default settings.
The projector enters the standby mode to reflect the setting values.
[REGISTERED SIGNAL]
Deletes all the setting values saved for each input signal.
To delete only a part of a registered signal, perform the procedure described in “Deleting the
registered signal” (
x
page 149).