pin 1 on D-Board
H.V. measurement
4. Connect a H.V. meter (static type, class 0.1) with high voltage
leads to high voltage distributor on FBT.
DVM and power supply connection
5. Connect the 15 ~ 25 V DC variable power supply positive lead to
D34 or IC802 pin 2 (D Board) and negative lead to heat sink of
Q551 or D825
Procedures:
1. Apply a NTSC white pattern.
2. Turn PTV ON.
3. Adjust the picture or brightness controls so that the DVM reads
12.4 ± 0.4 volts.
4. Increase the variable power supply until set turns off. The set
should turn off at 12.4 ± 0.4 volts (DVM) and high voltage less than
36.4kV.
5. If the DVM reading is other than 12.4 ± 0.4 volts, readjust picture or
brightness control and repeat steps 3.
6. Turn off the variable supply and confirm that the set will turn on
with the remote control.
6
Summary of Contents for PT-56WX53G
Page 82: ...5 PTV Location of controls 10 ...
Page 93: ...A BOARD 21 ...
Page 94: ...D BOARD 22 ...
Page 95: ...R BOARD VIEW DC BOARD TOP VIEW 23 ...
Page 96: ...DC BOARD BOTTOM VIEW DV BOARD 24 ...
Page 97: ...DG BOARD TOP VIEW DG BOARD BOTTOM VIEW 25 ...
Page 147: ...19 5 Instructional flow for service mode 75 ...
Page 148: ...76 ...
Page 149: ...20 Reference of PDF links color 21 Conductor views 77 ...
Page 151: ...22 2 Video block diagram 23 Schematic diagrams 23 1 Schematic diagrams notes 79 ...
Page 152: ...80 ...
Page 153: ...23 2 Notas de los diagramas esquematicos 81 ...
Page 154: ...82 ...
Page 159: ...87 ...
Page 162: ...90 ...
Page 164: ...92 ...
Page 166: ...94 ...
Page 168: ...96 ...
Page 170: ...98 ...
Page 176: ...Q 104 ...
Page 178: ...Q 106 ...
Page 184: ...112 ...
Page 186: ...114 ...
Page 189: ...117 ...
Page 191: ...119 ...