3. Important safety tests
Measuring H.V.
The anode caps are cemented to the CRTs. To gain access for high voltage measurement,
remove the red CRT’s anode lead from the flyback transformer distributor. Grasp the anode lead
protective cap at its bottom and squeeze it against thelocking cap body inside, rotate 1/4 turn
counter clockwise and pull the anode lead sleeve out of the FBT distributor. Connect a high
voltage positive lead from your H.V. meter to the FBT distributor, and the common negative lead
to cold ground
FBT leads removal
Note:
Reinsert the anode lead into the FBT distributor until it is tightly and fully seated. Turn the
locking cap clockwise to lock in place.
(EHT) Protector operation check
With the cabinet back removed, apply a nominal 120V A.C. to the PTV.
Over voltage test
Preparation:
1. Turn PTV “OFF”
2. Connect a NTSC signal generator to the antenna terminal.
3. Connect DVM positive lead to D31 pin 2 and negative lead to D31
5
Summary of Contents for PT-56WX53G
Page 82: ...5 PTV Location of controls 10 ...
Page 93: ...A BOARD 21 ...
Page 94: ...D BOARD 22 ...
Page 95: ...R BOARD VIEW DC BOARD TOP VIEW 23 ...
Page 96: ...DC BOARD BOTTOM VIEW DV BOARD 24 ...
Page 97: ...DG BOARD TOP VIEW DG BOARD BOTTOM VIEW 25 ...
Page 147: ...19 5 Instructional flow for service mode 75 ...
Page 148: ...76 ...
Page 149: ...20 Reference of PDF links color 21 Conductor views 77 ...
Page 151: ...22 2 Video block diagram 23 Schematic diagrams 23 1 Schematic diagrams notes 79 ...
Page 152: ...80 ...
Page 153: ...23 2 Notas de los diagramas esquematicos 81 ...
Page 154: ...82 ...
Page 159: ...87 ...
Page 162: ...90 ...
Page 164: ...92 ...
Page 166: ...94 ...
Page 168: ...96 ...
Page 170: ...98 ...
Page 176: ...Q 104 ...
Page 178: ...Q 106 ...
Page 184: ...112 ...
Page 186: ...114 ...
Page 189: ...117 ...
Page 191: ...119 ...