83
PAW-VP•LDHW - Technical Manual – 2019-11
System drawings
6
6.2 System PACi/ECOi DHW
(Field supplied) accessories
1. Pressure control valve if inlet city water
is more than 6 bar (field supplied)
2.
Strainer (field supplied)
3. Expansion tank if check valve or pressure
control valve is mounted (field supplied)
4. Circulation water pump (e.g. Grund-
fos comfort UP 15–14 BA PM, field
supplied)
5.
Safety valve 6 or 9.5 bar (field supplied)
6.
Temperature control valve (field
supplied)
7. Water pipe inlet/outlet VP1000L/750
(35 mm) VP500L/200 (22 mm)
8. PAW-VP RTC5B PAC/ECO controller
For a hotel or apartment complex where the last room is more than 30 meters away from the
DHW tank, a water pump (for example type Grundfos comfort UP 15-14 BA PM) should be
installed in order to obtain hot water quickly.
Remember to install a return pipe for pump circulation of maximum Ø15 mm and make sure that
supply and return pipes are well insulated for minimal heat loss.
Standard system
with circulation pipe and
temperature control system
DHW
City Water in
Ø15 mm max.
1
2
3
8
7
7
6
5
4
Summary of Contents for PAW-VP1000LDHW
Page 2: ......
Page 122: ...122 PAW VP LDHW Technical Manual 2019 11 Appendix A A 2 Spare parts Tanks ...
Page 123: ...123 PAW VP LDHW Technical Manual 2019 11 Appendix A ...
Page 124: ...124 PAW VP LDHW Technical Manual 2019 11 Appendix A ...
Page 125: ...125 PAW VP LDHW Technical Manual 2019 11 Appendix A ...
Page 126: ...126 PAW VP LDHW Technical Manual 2019 11 Appendix A ...
Page 132: ......
Page 133: ......
Page 134: ...Polar Energi AS Postboks 117 9450 Hamnvik Norway www polarenergi com ...