6.1 System PAC DHW
For a hotel or apartment complex where the last room is more than 30 meters away from the
DHW tank, a water pump (for example type Grundfos comfort UP 15-14 BA PM) should be
installed in order to obtain hot water quickly.
Remember to install a return pipe pump circulation of maximum Ø15 mm and make sure that
supply and return pipes are well insulated for minimal heat loss.
DHW
DHW
City Water in
Outdoor unit
Standard system 1:1
without circulation
Standard system 1:1
with circulation pipe
Outdoor unit
DHW tank
DHW tank
Qmin = 1 litre/minute
Water pump operation schedule
At night
ON 15 min
OFF 80 min
Through the day ON 15 min
OFF 40 min
City Water in