7
7.4.2 How to connect temp sensors TA, E1, E2, E3 to the tank system
Terminal PAW-VP-RTC5B-PACi
i
Note
Remember that the E2 sensor is required.
!
Important
When using RTC5B PACi together with DHW tank remove jumper for E2-E2 and connect the sensor E2.
Terminal PAW-VP-RTC5B-ECOi
!
Important
When using RTC5B ECO together with ECOi MF3 DHW tank and air to air indoor unit remem
-
ber to install adapter CZ-CAPE2 for solenoid valve kit.
7.4.3 How to mount the E1, E2 and E3 sensors on the pipes
Maximum contact
Most sensitive point of the thermistor
Cover the thermistor and the pipe with
aluminum tape, then the aluminum
tape with thermal insulation.