Camera Recording
Camera Recording (continued)
Using the LCD Monitor
View recording scene on the LCD (Liquid
Crystal Display) monitor.
1
Press LCD-OPEN to unlock LCD
monitor.
2
Swing LCD monitor fully open and
adjust viewing angle.
Caution:
Rotating partially open LCD monitor
may block cassette door and damage
Camcorder body.
3
Set POWER to CAMERA.
• LCD monitor turns on/off by the
POWER switch.
• EVF shuts off when LCD monitor is
opened and turns back on when
LCD is closed.
• Both EVF and LCD monitor turn on
when LCD is at 180 (see above
left).
This allows both you and the subject
to view the recording.
4
Turn BRIGHT control to adjust LCD
monitor brightness level.
5
Press RECORD/PAUSE to start
recording.
Note:
• Using LCD monitor reduces battery operation
time.
• Return LCD monitor to locked position when not
in use.
2
3
1
4
LCD-OPEN
BRIGHT
5
Before you begin...
• Connect Camcorder to power source.
• Insert cassette with record tab.
CAMERA
OFF
VCR
REC
90
180
(PV-L650 shown)
(PV-L550/PV-L600/PV-L650/VM-L450)
Stand-by Quick Release
If left in RECORD/PAUSE mode for 5 minutes, Camcorder switches to Stand-by mode to
conserve battery. When set to ON, Stand-by Quick Release lets you resume recording by
pressing RECORD/PAUSE two times. New camcorders will default to OFF.
Before you begin...
• Connect Camcorder to power source.
• Insert cassette with record tab.
1
Set POWER to CAMERA.
2
Press MENU for MENU mode.
Press UP or DOWN to select
STAND-BY RELEASE
.
3
Press DISPLAY to select ON/OFF.
ON: From Stand-by mode,
press RECORD/PAUSE two times
to resume recording.
OFF: From Stand-by mode,
set POWER to OFF, then to
CAMERA.
Press RECORD/PAUSE to record.
4
Press MENU to exit.
RECORD/
PAUSE
1
2
,
3
,
4
CAMERA
OFF
VCR
REC
DISPLAY
MENU
UP
DOWN
SELECT : PUSH
SELECT : PUSH // KEY
KEY
SET : PUSH DISPLAY KEY
SET : PUSH DISPLAY KEY
END : PUSH MENU KEY
END : PUSH MENU KEY
PROGRAMMED REC
PROGRAMMED REC
TITLE
; AUTO/MANUAL
; AUTO/MANUAL
TALLY LAMP
TALLY LAMP
; ON
; ON
STAND-BY RELEASE
; OFF
; OFF
CLOCK SET
CLOCK SET
- - - MENU - - - PAGE 1/2
Easy Edit Stand-by
For a smooth transition between scenes if
recording is stopped, and then started within
24 hours.
1
Press RECORD/PAUSE to stop
recording.
2
Set POWER to OFF and leave
cassette in Camcorder.
3
To resume recording, set POWER
to CAMERA.
4
Press RECORD/PAUSE to resume
recording.
Note:
• Use Manual Easy Edit (below) if more than
24 hours before recording is resumed.
2
3
1
,
4
Before you begin...
• Connect Camcorder to power source.
• Insert cassette with record tab.
CAMERA
OFF
VCR
REC
REC
Manual Easy Editing
For proper continuity when taping from Stop
mode or after attaching a new Battery.
1
3
4
2
1
Set POWER to VCR.
2
A
Press REWIND/SEARCH to
rewind a few seconds of tape.
B
Press PLAY to review recording.
C
Press STILL where you want to
continue recording.
3
Set POWER to CAMERA.
4
Press RECORD/PAUSE to resume
recording.
STOP
STILL
PLAY
REW
FF
B
C
A
Before you begin...
• Connect Camcorder to power source.
• Insert cassette with record tab.
CAMERA
OFF
VCR
REC
REC
Before you begin...
•
Connect Camcorder to power source.
Use AC Adaptor for longer recordings.
•
Insert cassette with record tab.
•
Set POWER to CAMERA.
1
Press MENU for MENU mode.
Press UP or DOWN
to select
PROGRAMMED
REC
.
2
Press DISPLAY. (Current time is
displayed.)
Each additional press of DISPLAY
increases start
time by 30
minutes.
3
Press DOWN
to select
REC
TIME
. Press DISPLAY repeatedly to
select one of the options shown at
the left.
To cancel the setup, press MENU
twice.
4
Press RECORD/PAUSE to place
Camcorder in stand-by mode.
Recording will be done as scheduled.
Programmed Recording
Set a recording start and stop time. Or, set
a 5 or 10 second interval recording to be
done each minute.
*1 Interval 5 SEC/MIN:
Record 5 seconds each minute.
*2 Interval 10 SEC/MIN:
Record 10 seconds each minute.
10MIN.
20MIN.
30MIN.
TO TAPE END
INTERVAL
5 SEC/MIN.
INTERVAL
10 SEC/MIN.
* 2
* 1
Note:
• Start time may not be set over 24 hours
from current time.
• Camcorder shuts off at tape end, or 12
hours after Interval Recording starts.
• To cancel, set POWER to OFF.
4
1
,
2
,
3
DISPLAY
MENU
UP
DOWN
SELECT : PUSH
SELECT : PUSH // KEY
KEY
SET : PUSH DISPLAY KEY
SET : PUSH DISPLAY KEY
END : PUSH MENU KEY
END : PUSH MENU KEY
PROGRAMMED REC
PROGRAMMED REC
TITLE
TITLE
; AUTO/MANUAL
; AUTO/MANUAL
TALLY LAMP ; ON
TALLY LAMP ; ON
STAND-BY RELEASE ; OFF
STAND-BY RELEASE ; OFF
CLOCK SET
CLOCK SET
- - - MENU - - - PAGE 1/2
- - - MENU - - - PAGE 1/2
START
START
;
; 10 : 20PM
10 : 20PM
REC
REC TIME
TIME ; 10MIN.
; 10MIN.
10:20:00
10:20:00PM
PM
SELECT : PUSH
SELECT : PUSH // KEY
KEY
SET : PUSH DISPLAY KEY
SET : PUSH DISPLAY KEY
START : PUSH RECORD KEY
START : PUSH RECORD KEY
CANCEL: PUSH MENU KEY
CANCEL: PUSH MENU KEY
START ;
START ; 10 : 20PM
10 : 20PM
REC TIME
; 10MIN.
; 10MIN.
10:20:00
10:20:00PM
SELECT : PUSH
SELECT : PUSH // KEY
KEY
SET : PUSH DISPLAY KEY
SET : PUSH DISPLAY KEY
START : PUSH RECORD KEY
START : PUSH RECORD KEY
CANCEL: PUSH MENU KEY
CANCEL: PUSH MENU KEY
START ;
START ; 10:20PM
REC
REC TIME ; 10MIN.
TIME ; 10MIN.
10:20:00
10:20:00PM
PM
JUN
JUN 1
2000
1 2000
STAND-BY
6
PV-D300 / VM-D100 / PV-L550 / PV-L600 / PV-L650 / VM-L450
Summary of Contents for Palmcorder Palmsight PV-L650
Page 3: ...1 1 1 MECHANICAL REPLACEMENT PARTS LIST 1 1 2 ELECTRICAL REPLACEMENT PARTS LIST 3 ...
Page 13: ...Fig 1 1 11 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 17: ...15 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 18: ...16 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 19: ...17 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 20: ...5 1 5 DESCRIPTION OF EMERGENCY INDICATIONS 18 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 41: ...6 1 9 3 Battery Catcher Unit Fig D13 3 39 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 49: ...6 2 7 P C B Angle Fig DM5 47 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 53: ...Fig DM9 2 6 2 12 A C Head Unit Fig DM10 51 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 60: ...Fig DM21 2 Fig DM21 3 59 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 63: ...62 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 69: ...7 3 2 INITIAL GUIDELINE 68 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 72: ...71 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 76: ...7 4 TEST POINTS AND CONTROL LOCATION 75 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 125: ...11 2 CAMERA AND FRAME SECTION PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 126 ...
Page 126: ...11 3 FRAME SECTION A B PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 127 ...
Page 127: ...11 4 FRAME AND LCD SECTION C D E F PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 128 ...
Page 128: ...11 5 COLOR EVF SECTION A PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 129 ...
Page 129: ...11 6 EVF SECTION B C D E F PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 130 ...