7.2.2.5. A/C HEAD HORIZONTAL
POSITION ADJUSTMENT
Purpose:
To adjust the Horizontal Position of the
A/C Head.
Symptom of
Misadjustment:
If the Horizontal Position of the A/C Head
is not properly adjusted, maximum
envelope can not be obtained at the
Neutral Position of the Tracking Control
Circuit.
1. Put the unit into the service mode "I. Tracking Fix" to defeat
Auto
Tracking.
Refer
to
"SERVICE
MODE
SPECIFICATION" in "SERVICE NOTES."
2. Connect the oscilloscope to Pin 30 (Envelope signal) on the
TP Adjustment P.C.B. Use Pin 33 (Head Switch signal) as
a trigger.
3. Play back the Alignment Tape (VFMS0004H6C).
4. Set the Screwdriver into the Hole (A) as shown.
Fig. M6-1
5. Slowly move the A/C Head Unit to the direction "A" or "B" as
shown so that the envelope is at maximum.
Fig. M6-2
6. To find the center of the maximum period of the envelope,
move the A/C Head Unit to confirm the limits on either side
of the maximum period.
Note:
It will be possible to confirm step 6) after performing the
following steps.
a. Exit the "I. Tracking Fix" mode, then skip the "J. PG
Shifter" mode to enter other modes (except these 2). Or,
close the service mode.
b. Press the Tracking Control Up Button on the camcorder
several times (count the number of times pressed) until
the maximum envelope is reduced to 1/2.
c.
Press the Tracking Control Down Button on the
camcorder several times (count the number of times
pressed) until the maximum envelope is reduced to 1/2.
d. If the number of pressing is not the same, readjust
A/C Head horizontal position.
7.2.2.6. CONFIRMATION OF ENVELOPE
OUTPUT
Purpose:
To achieve a satisfactory picture and
secure precise tracking.
Symptom of
Misadjustment:
If the envelope is output poorly, much
noise will appear in the picture. Then the
tracking will lose precision and the
playback picture will be distorted by any
slight variation of the tracking control
circuit.
1. Connect the oscilloscope to Pin 30 (Envelope signal) on the
TP Adjustment P.C.B. Use Pin 33 (Head Switch signal) as
a trigger.
2. Play back the Alignment Tape (VFMS0004H6C).
3. Confirm that the envelope waveform is as flat as possible
(V1/V(max)> 0.7).
If adjustment is required, adjust S Post and/or T Post with
"—" Screwdriver. Refer to "Envelope Output Adjustment."
Fig. M7
66
PV-D300 / VM-D100 / PV-L550 / PV-L600 / PV-L650 / VM-L450
Summary of Contents for Palmcorder Palmsight PV-L650
Page 3: ...1 1 1 MECHANICAL REPLACEMENT PARTS LIST 1 1 2 ELECTRICAL REPLACEMENT PARTS LIST 3 ...
Page 13: ...Fig 1 1 11 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 17: ...15 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 18: ...16 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 19: ...17 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 20: ...5 1 5 DESCRIPTION OF EMERGENCY INDICATIONS 18 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 41: ...6 1 9 3 Battery Catcher Unit Fig D13 3 39 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 49: ...6 2 7 P C B Angle Fig DM5 47 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 53: ...Fig DM9 2 6 2 12 A C Head Unit Fig DM10 51 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 60: ...Fig DM21 2 Fig DM21 3 59 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 63: ...62 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 69: ...7 3 2 INITIAL GUIDELINE 68 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 72: ...71 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 76: ...7 4 TEST POINTS AND CONTROL LOCATION 75 PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 ...
Page 125: ...11 2 CAMERA AND FRAME SECTION PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 126 ...
Page 126: ...11 3 FRAME SECTION A B PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 127 ...
Page 127: ...11 4 FRAME AND LCD SECTION C D E F PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 128 ...
Page 128: ...11 5 COLOR EVF SECTION A PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 129 ...
Page 129: ...11 6 EVF SECTION B C D E F PV D300 VM D100 PV L550 PV L600 PV L650 VM L450 130 ...