1. Insert the alignment tape.
2. Press and hold VCR/TV button and CH DOWN buttons on VCR
together over 5 seconds in power off condition.
The power comes on and the unit goes into service mode.
3. Play back the alignment tape.
4. To enter Tracking center mode, press PLAY button in Play back
mode. "TRACKING CENTER" will be displayed on the TV monitor.
5. Connect the oscilloscope to TP3002 on the Video Signal Process
Section of the Main C.B.A. Use TP6205 as a trigger.
6. Confirm that the RF envelope is flat enough (V1/V-max. is 0.7 or
more). If not, with Post Adjustment Driver, adjust P2 and P3 post
height so that the envelope waveform becomes as flat (V1/V-max.
is 0.7 or more) as possible (No envelope drop). If the envelope
drop appears on the left-half of the waveform, adjust P2 post
height. If the envelope drop appears on the right-half of the
waveform, adjust P3 post height.
CAUTION:
Overtightening P2 and P3 posts may cause the threads to strip.
Note:
It will be possible to confirm Step 6 according to following steps.
1. Release the Tracking center mode.
2. Press the Tracking Control Up or Down button on remote control.
Make sure that the envelope waveform remains flat. If not,
readjust P2 and/or P3 post heights.
Fig. M4-1
Fig. M4-2
49
Summary of Contents for Omnivision PV-V4621
Page 6: ...Fig 1 3 Fig 1 4 Fig 1 5 6 ...
Page 26: ...6 2 2 Inner Parts Location Fig J1 1 26 ...
Page 27: ...6 2 3 EJECT Position Confirmation Fig J1 2 27 ...
Page 58: ...11 2 MECHANISM BOTTOM SECTION 58 ...
Page 59: ...11 3 CASSETTE UP COMPARTMENT SECTION 59 ...
Page 60: ...11 4 CHASSIS FRAME AND CASING PARTS SECTION 60 ...
Page 61: ...11 5 PACKING PARTS AND ACCESSORIES SECTION 61 ...