metal particles).
Confirmation of Signal Level
1. Place the unit in Service Position (2-1), (2-2). Refer to "
SERVICE
POSITION
" in SERVICE NOTES.
2. Supply a Video Signal to the video input jack.
3. Insert a cassette tape and place the unit in SLP recording mode.
4. Connect the oscilloscope to Pin 9 of P6201 on the Main C.B.A. Confirm
that the signal level is greater than 20 mV [P-P].
Fig. M3-2
7.2.2.3. TAPE INTERCHANGEABILITY ADJUSTMENT
Note:
To perform these adjustment/confirmation procedures, enter the
Tracking center mode.
Equipment Required:
Dual Trace Oscilloscope
VHS Alignment Tape (VFMS0003H6)
Post Adjustment Driver (VFK0329)
H-Position Adjustment Driver (VFK0330)
7.2.2.3.1. ENVELOPE OUTPUT ADJUSTMENT
The height of the P2 and P3 Posts replacement part is preadjust at the factory.
Purpose:
To achieve a satisfactory picture and secure precise tracking.
Symptom of Misadjustment:
If the envelope is output poorly, much noise will appear in the picture.
Then the tracking will lose precision and the playback picture will be
57
Summary of Contents for OmniVision PV-QV201
Page 9: ...2 Fault indication will be displayed in F I P as shown Fig 2 2 FIg 2 3 9 ...
Page 13: ...5 1 4 1 3 Service Position 2 2 Model M N Fig 4 2 2 13 ...
Page 27: ...Fig D2 6 1 2 1 Notes in chart 27 ...
Page 30: ...Fig D5 2 30 ...
Page 32: ...32 ...
Page 33: ...6 2 2 Inner Parts Location Fig J1 1 33 ...
Page 34: ...34 ...
Page 36: ...Fig J2 1 2 36 ...
Page 67: ...11 2 MECHANISM BOTTOM SECTION 67 ...
Page 68: ...11 3 CASSETTE UP COMPARTMENT SECTION 68 ...
Page 70: ... Model PV V4511 PV V4521 PV V4521 K VHQ 451 70 ...
Page 71: ... Model PV V4611 71 ...
Page 73: ... Model PV V4611 73 ...
Page 78: ...12 2 MECHANICAL REPLACEMENT PARTS LIST MECHANICAL REPLACEMENT PARTS 78 ...
Page 81: ... 81 ...
Page 88: ... 88 ...
Page 90: ...90 ...
Page 95: ...95 ...
Page 105: ...105 ...
Page 109: ...109 ...
Page 145: ...1 2 Schematic Diagram Circuit Board Layout 2 ...