Symptom of Misadjustment:
If the FG Signal is not properly picked up, Servo Operation cannot be
achieved.
Equipment Required:
Oscilloscope
Specification:
0.1 mm ~ 0.13 mm
1. Remove the VCR Chassis Unit and then place it upside down.
2. Remove the Main C.B.A.
3. Slightly loosen Screw (A). Then set the Screwdriver (Phillips Driver)
into the Hole (A). Turn the screwdriver clockwise until the MR Head
touches the rotor. Then turn it slightly counterclockwise to make the
clearance as specified.
4. Tighten Screw (A).
5. Reinstall the Main C.B.A.
Fig. M3-1
Note:
Do not touch the outside circumference of the rotor surface with any
tool and keep magnetic material away from the rotor magnet (especially