6
*4 Controlled by ambient temperature and ice making sensor tempera-
ture.
*5 Controlled by ambient temperature and defrosting status.
2.3.
Electric Heater
*1.Diode half wave rectification *2.Series connection
Lihgt
PF(LED)
(for SC)
Model
PAS-F501T(PF Light board)
íËäi
5V / 25mA
Door switch
(mechanical)
(NC/NO)
Model
SDKNA20302 / D3D-121
(for right PC)
Rating
DC5V/2mA, DC5V1mA
Door switch
(non-con-
tactl)
Model
PAS-door SWboard S white
(for left PC)
Rating
DC5V/8mA
Door switch
(non-con-
tactl)
Model
PAS-door SWboard S red
Rating
DC5V/8mA
Item/Model
NR-F532TX,NR-F532TT
Door switch
(non-con-
tactl)
Model
PAS-F500T(door SW board)
(for FC)
Rating
DC5V/8mA
Power cord
2.1m(valid length)
Item/Model
NR-F532TX,NR-F532TT
Heater name
Desti-
nation
Rated volt-
age(V)
Heat
value
(W)
Resis-
tance(
Ω
)
Power system
Purpose
FC defrost heater
S3/X3
220
200
242 Powered during defrosting
Evaporator defrost
S6/S7
235
200
276
Egg heater
S3/X3
220
2.2
22,278 Powered synchronize with ambient temperature, ice
making/freezer temperature, and selectable comp-
ertment temperature adjustment
Prevents eggs freezing
S6
230
2.4
S7
240
2.6
Supply water pipe
heater *1 (with ther-
mal fuse 94
°
C)
S3/X3
220:155.6
2.7
9,006
Almost always powered
Prevents water supply pipe
freezing
S6
230:162.6
2.9
S7
240:169.7
3.6
Evaporator cover
heater
S3/X3
220
4.6
1,0444 Powered synchronize with ambient temperature, ice
making/freezer temperature, and selectable com-
partment temperature adjustment
Prevents dewing at back of
vergetable compartment
S6
230
5.1
S7
240
5.5
VC heater *2
S3/X3
220:187.0
4.6
3,120 Powered synchronize with ambient temperature,
freezer temperature, and refrigerator/selectable/
freezer
temperature adjustment
Compensating vegetable
compartment temperature
S6
230:195.5
12.3
S7
240:204.0
13
IS duct heater *2
S3/X3
220:33.0
2
550
Prevents duct from freezing
S6
230:34.5
2.2
S7
240:36
2.4
French heater
S3/X3
220
4.8
10,030
Powered synchronize with ambient temperature and
refrigerator temperature adjustment
Prevents dewing on fefriger-
ator partitions
S6
230
5.2
S7
240
5.7
Summary of Contents for NR-F532TT
Page 8: ...8 3 General Introduction 3 1 Flow of Refrigerant 3 2 Flow of cold air inside compartments ...
Page 9: ...9 3 3 Flow of cold air duct ...
Page 10: ...10 4 Features 4 1 Self cleaning of the whole compartment ...
Page 18: ...18 6 Location of Controls and Components 6 1 Components ...
Page 19: ...19 6 2 Control panel and Control button ...
Page 24: ...24 11 Troubleshooting Guide 11 1 Not cooling at all Compressor does not run ...
Page 28: ...28 11 5 Ice cubes can not be made FC cooling condition is normal ...
Page 45: ...45 13 Maintenance 13 1 KNACK FOR MAINTENANCE ...
Page 46: ...46 13 2 MAINTENANCE OF ICE MAKER ...
Page 47: ...47 14 Dimensions 14 1 OUTSIDE ...
Page 48: ...48 14 2 INSIDE ...
Page 49: ...49 14 3 BOTTOM ...
Page 50: ...50 15 Wiring Connection Diagram 15 1 SCHEMATIC DIAGRAM ...
Page 51: ...51 16 Exploded View and Replacement Parts List 16 1 EXPLODED VIEW 1 ...
Page 54: ...54 16 3 EXPLODED VIEW 2 ...
Page 56: ...56 16 5 EXPLODED VIEW 3 ...
Page 58: ...58 16 7 EXPLODED 16 8 VIEW 4 ...
Page 60: ...60 16 10 EXPLODED VIEW 5 ...