31
8. Unscrew screw which fixes inject pipe cover. (1 piece)
(The screw is fixed on the ceiling of ice compartment.)
9. Insert screw driver (-) into triangle mark portion of inject
pipe cover and unhook inject pipe cover (4 portions.)
10. Disconnect connector of inject pipe A'ssy. (1 piece)
11. Lift up inject tube A'ssy and remove it.
CAUTIONS
• Set inject tube A'ssy in place firmly.
Otherwise, water leakage may happen.
• Connect connector firmly.
• Arrange electric wires so that these are not loosen.
12.1.3.
SENSOR PCC
1. Remove water supply corner and PC duct plate.
(Refer to "DISASSEMBLY OF PC COMPARTMENT" (1-
6).)
2. Remove screws for sensor cover and pull toward you.
3. Remove sensor PCC from sensor cover.
ASSEMBLY REPLACING sensor PCC
1. Cut the wire of sensor PCC.
2. Connect new sensor PCC to wire from cabinet.
(The Scotch lock is used for the connection.)
3. The Scoch lock is stored inside of sensor cover FC, and
fixed the sensor cover by screw.
12.1.4.
TWIN DAMPER THERMOSTAT
1. Remove PC duct plate
(Refer to "12.1.DISASSEMBLY OF PC")
2. Unscrew the screw of Damper cover (Harness cover),
then remove Damper cover.
3. Disconnect the connector of the Damper
(Measure resistance of the Damper when it is needed.)
4. Remove INS duct cover TOP
CAUTIONS
INS duct cover is going to be broken easily, therefore
new INS duct cover is sent with the Damper when it is
ordered.
a. Cut the Seal tape (yellow) by a cutter along joint part
on INS duct cover TOP side.
b. Same as above, cut Foam tape (white) on front side.
c. Pull the wire harness to the right and remove INS duct
cover TOP.
Summary of Contents for NR-F532TT
Page 8: ...8 3 General Introduction 3 1 Flow of Refrigerant 3 2 Flow of cold air inside compartments ...
Page 9: ...9 3 3 Flow of cold air duct ...
Page 10: ...10 4 Features 4 1 Self cleaning of the whole compartment ...
Page 18: ...18 6 Location of Controls and Components 6 1 Components ...
Page 19: ...19 6 2 Control panel and Control button ...
Page 24: ...24 11 Troubleshooting Guide 11 1 Not cooling at all Compressor does not run ...
Page 28: ...28 11 5 Ice cubes can not be made FC cooling condition is normal ...
Page 45: ...45 13 Maintenance 13 1 KNACK FOR MAINTENANCE ...
Page 46: ...46 13 2 MAINTENANCE OF ICE MAKER ...
Page 47: ...47 14 Dimensions 14 1 OUTSIDE ...
Page 48: ...48 14 2 INSIDE ...
Page 49: ...49 14 3 BOTTOM ...
Page 50: ...50 15 Wiring Connection Diagram 15 1 SCHEMATIC DIAGRAM ...
Page 51: ...51 16 Exploded View and Replacement Parts List 16 1 EXPLODED VIEW 1 ...
Page 54: ...54 16 3 EXPLODED VIEW 2 ...
Page 56: ...56 16 5 EXPLODED VIEW 3 ...
Page 58: ...58 16 7 EXPLODED 16 8 VIEW 4 ...
Page 60: ...60 16 10 EXPLODED VIEW 5 ...