44
11.8.5. Install Door A'ssy PC
1. Remove the connector that connect with Door A'ssy PC
a. Remove the screw that is fixation of Cover Cap Door
PCT L.
b. Insert screwdriver (-) into a gap of Cover Cap Door
PCT L, and pry off hooks (2 portions).
Remove Cover Cap Door PCT L.
c. Insert screwdriver (-) into a gap of Cover Harness
PCT L, and pry off hooks (3 portions).
Remove Cover Harness PCT L.
d. Pull out the connector that is connected with Door
A'ssy PC, and remove the connector while pressing
toward upper side.
e. Store the connector in Cover Harness PCT, install
Cover Harness PCT in Door A’ssy PC as before.
2. Install Door A'ssy PC
a. Apply the grease on around Pin Hinge Center.
b. Lift Door A’ssy PC, and insert left bottom of Door A’ssy
PC into Hinge Center L.
3. Install Hinge Top L
a. Through the connector to the hole of Hinge Top L.
CAUTION
• Be careful not to forcibly bend when the connector is
through the hole of Hinge Top L. Because it might be
cause to wire cut and connector damage.
b. Apply the grease on the tongue of Hinge Top L and
insert it into Door A’ssy PC.
c. Three screws that are fixation of Hinge Top L are tem-
porarily screwed.
Summary of Contents for NR-B32FW2
Page 6: ...6 3 General Introduction 3 1 Flow of Refrigerant And Air ...
Page 7: ...7 4 Features 4 1 Features 4 1 1 High Efficiency Cabinet ...
Page 8: ...8 4 1 2 Storage Solution ...
Page 9: ...9 4 1 3 Refrigerator Compartment 4 1 4 Hygiene Active and Multi Airflow ...
Page 10: ...10 4 1 5 Vegetable Case 4 1 6 Vitamin Safe ...
Page 11: ...11 4 1 7 Hygiene Active ...
Page 18: ...18 6 2 Components ...
Page 19: ...19 7 Installation Instructions 7 1 Installation Instructions ...
Page 20: ...20 ...
Page 21: ...21 7 2 Setting the temperature ...
Page 22: ...22 7 3 Using the handy functions ...
Page 27: ...27 10 Troubleshooting Guide 10 1 FC and PC not cooling at all Compressor does not run ...
Page 28: ...28 10 2 PC is not cooling or poor cooling FC cooling condition is normal ...
Page 29: ...29 10 3 FC is poor cooling Compressor run ...
Page 30: ...30 10 4 VC is poor cooling or excessive cooling ...
Page 48: ...48 12 Maintenance ...
Page 49: ...49 ...
Page 50: ...50 ...
Page 51: ...51 13 Dimensions 13 1 Outside NR B32FX2 NR B32FW2 ...
Page 52: ...52 13 2 Inside NR B32FX2 NR B32FW2 ...
Page 53: ...53 14 Schematic Diagram 14 1 Schematic Diagram NR B32FX2 NR B32FW2 ...
Page 54: ...54 15 Exploded View and Replacement Parts List 15 1 Exploded View 1 NR B32FX2 NR B32FW2 ...
Page 57: ...57 15 3 Exploded View 2 NR B32FX2 NR B32FW2 ...
Page 60: ...60 15 5 Exploded View 3 NR B32FX2 NR B32FW2 Bundled parts The parts for left opening doors ...
Page 62: ...62 15 7 Packing Exploded View NR B32FX2 NR B32FW2 ...