15
5.2.
Defrost Control
FC defrost period control corresponding to each ATC.
5.3.
Photosynthesis-freshness-improving effect control
Input: The vitamin mode ON.
Output: LED of VC (Green LED, Blue LED)
5.4.
FC Fan Control
5.5.
Compressor Rotational Speed Control
For securing the amount of cooling according to the overload at a high ambient temperature, the rotational speed of the compressor
is changed by difference of temperature between FCC and FC Control setting, PCC and PC Control setting.
Detection : FCC, PCC, ATC sensor
5.5.1.
The use rotational speed
• The rotational speed of compressor is changed by deference between FCC temperature standard value (ON temperature) and
FCC temperature, PCC temperature standard value (ON temperature) and PCC temperature.
The rotational speed according to ambient temperature is as follows, it doesn't drive in other rotational speeds.
• The use rotational speed
*Notes
In case of setting of “Super Freeze”, the rotational speed of “Super Freeze” take precedence.
5.6.
Compressor starting control
The compressor is not start while waiting timer is operating.
And when power is turned on, compressor staring control is not available.
5.7.
Demo Control
To promote in-store sales.
5.7.1.
Start
Simultaneously open FC door and PC door and press "Up" and "Down" buttons for 10 seconds to start demo control.
However, demo control is not performed after initial defrosting.
Vitamin mode
LED
Operation
ON
Blue LED
Flashing
Green LED
Flashing
OFF
Blue LED
Off
Green LED
Off
ATC
Compressor
FC fan
12
°
C
ON
ON
OFF
OFF
13
°
C
22
°
C
ON
ON
OFF
OFF
23
°
C
ON
ON
OFF
OFF
Setting rotational speed of compressor
Rotational speed
R1
R2
R3
R4
R5
Setting value r/s
25
39
43
59
71
After power turning on
0 minute
After FC Defrost stopping (Improvement of start after defrost)
3 minutes
After compressor stopping (Prevention of trip when re-starting)
10 minutes
Sequence protection
10 minutes
Summary of Contents for NR-B32FW2
Page 6: ...6 3 General Introduction 3 1 Flow of Refrigerant And Air ...
Page 7: ...7 4 Features 4 1 Features 4 1 1 High Efficiency Cabinet ...
Page 8: ...8 4 1 2 Storage Solution ...
Page 9: ...9 4 1 3 Refrigerator Compartment 4 1 4 Hygiene Active and Multi Airflow ...
Page 10: ...10 4 1 5 Vegetable Case 4 1 6 Vitamin Safe ...
Page 11: ...11 4 1 7 Hygiene Active ...
Page 18: ...18 6 2 Components ...
Page 19: ...19 7 Installation Instructions 7 1 Installation Instructions ...
Page 20: ...20 ...
Page 21: ...21 7 2 Setting the temperature ...
Page 22: ...22 7 3 Using the handy functions ...
Page 27: ...27 10 Troubleshooting Guide 10 1 FC and PC not cooling at all Compressor does not run ...
Page 28: ...28 10 2 PC is not cooling or poor cooling FC cooling condition is normal ...
Page 29: ...29 10 3 FC is poor cooling Compressor run ...
Page 30: ...30 10 4 VC is poor cooling or excessive cooling ...
Page 48: ...48 12 Maintenance ...
Page 49: ...49 ...
Page 50: ...50 ...
Page 51: ...51 13 Dimensions 13 1 Outside NR B32FX2 NR B32FW2 ...
Page 52: ...52 13 2 Inside NR B32FX2 NR B32FW2 ...
Page 53: ...53 14 Schematic Diagram 14 1 Schematic Diagram NR B32FX2 NR B32FW2 ...
Page 54: ...54 15 Exploded View and Replacement Parts List 15 1 Exploded View 1 NR B32FX2 NR B32FW2 ...
Page 57: ...57 15 3 Exploded View 2 NR B32FX2 NR B32FW2 ...
Page 60: ...60 15 5 Exploded View 3 NR B32FX2 NR B32FW2 Bundled parts The parts for left opening doors ...
Page 62: ...62 15 7 Packing Exploded View NR B32FX2 NR B32FW2 ...