9.4. Trouble related to Digital Programmer Circuit
SYMPTOM
STEP
CHECK
RESULT
CAUSE/CORRECTIONS
No display when oven is first plugged
in
1
Fuse pattern of D.P.C.
Normal
→
Step2
Open
Replace D.P.C. or Fuse
Pattern
2
Low voltage transforment (L.V.T.)
secondary voltage
Abnormal 0V
L.V.T.
Normal
→
Step3
3
IC10 pin5 voltage
Abnormal
IC10
Normal=5V
IC1, CX320, Display
No key input
1
Membrane switch continuity
Abnormal
Membrane switch
Normal
IC1
No beep sound
1
IC1 pin 8 voltage
Abnormal
IC1
Normal=5V
BZ210, Q210
Power relay A(RY2) does not turn on
even though the program had been set
and the start pad is tapped
1
IC1 pin 22 voltage while operation
Abnormal
IC1
Normal=5V
→
Step2
2
IC220 pin13 voltage
Abnormal
IC220
Normal 0.7V
RY2
No microwave oscillation at any power
1
IC1 pin 24 voltages while operation at high
power
Abnormal
IC1
Normal=5V
→
Step2
2
IC220 pin11 voltage
Abnormal
IC220
Normal 0.7V
→
Step3
3
Short circuit between collector and emittes
of Q227
Still not turn on
RY1
RY1 turns on
Q227, Q224,Q225,Q226
Dark or unclear display
1
Replace display and check operation
Normal
Display
Abnormal
IC1
Missing or lighting of unnecessary
segment
1
Replace IC1 and check operation
Normal
IC1
Abnormal
Display
H95/H97/H98 appears in window and
oven stops operation.Program High
power for 1 minute and conduct
following test quickly, unless
H95/H97/H98 appears and oven stops
1
Unplug CN702 (2 pin) connector and
measure voltage between terminals
Abnormal=0V
1. Latch Switch
2. D.P.C. /Power Relay
Normal=220~240V
→
Step2
2
Unplug CN701 (3 pin) connector and
measure pin3 voltage
Abnormal=0V
D.P.C.
Approx. AC 3V
Magnetron
9.5. Simple way of H.V. Inverter/magnetron troubleshooting
Purpose:
Simple way
(3/23 seconds rule)
of identifying whether it’s Magnetron, Inverter or others.
Set-up:
The unit under question is connected through the Ammeter as shown below.
Procedure:
Follow the matrix table below to identify the problem source.
Note:
Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this
procedure.
Power will:
Ammeter reading is:
To do:
Remedy:
Shut off in 23 seconds
after “Start”.
1. Between 0.5A and 1.0A.
Check and repair open magnetron circuit
CN703
Open magnetron wiring between Inverter
and magnetron terminal.
2. Between 1.0A and 2.0A.
Check continuity of D702 in Inverter PCB.
1. D702 shorted
Replace
H.V.Inverter
(F606YM300BP)
2. D702 is OK
Replace
magnetron
Shut off in 3 seconds
after “Start”
1. Less than 0.5A
Check open circuit: Latch Switch, DPC,
Power Relay, CN701 and CN702
Replace
defective
component(s),
or
correct switch, cables and connectors.
30
NN-CS599S
Summary of Contents for NN-CS599S
Page 2: ...2 NN CS599S ...
Page 3: ...3 NN CS599S ...
Page 5: ...1 FEATURE CHART 2 CONTROL PANEL 5 NN CS599S ...
Page 6: ...3 SCHEMATIC DIAGRAM 6 NN CS599S ...
Page 32: ...10 EXPLODED VIEW AND PARTS LIST 10 1 EXPLODED VIEW 32 NN CS599S ...
Page 40: ...11 DIGITAL PROGRAMMER CIRCUIT 11 1 SCHEMATIC DIAGRAM 40 NN CS599S ...
Page 41: ...41 NN CS599S ...