7.5. Inverter power supply (U)
DO NOT try to REPAIR H.V. Inverter power supply (U).
Replace complete H.V. Inverter(U) Unit.
WARNING: HIGH VOLTAGE
Test if failure codes H95, H97 or H98 appear when performing
the following procedure. It is recommended to use an AC line
input current ammeter for testing.
Test 1
1. With the oven unit’s AC power supply cord is unplugged
from the wall outlet, unplug the 2 pin H.V. connector CN703
from the magnetron tube.
2. Place 1 liter of water load into oven cavity.
3. Plug in the oven’s AC power supply cord into outlet.
4. Program DPC.
a. Press Timer/Clock pad twice.
b. Press Start button once.
c. Press Micro Power pad once.
5. Program oven at High power for 1 minute and press [Start]
button.
a. After approximately 23 seconds, oven stops operating.
b. During
oven
operation,
the
input
current
is
approximately 0.5 to 1A. If both a and b are OK,
proceed to test 2.
INPUT CURRENT
FAILURE CODE
Unplug CN703
0.5 to 1A
Oven stops in 23
seconds after started.
Test 2
Continued from Test 1
1. Unplug the oven’s AC power supply cord from outlet.
2. Unplug 3 pin connector CN701. CN703 remains unplugged.
3. Plug in the oven’s AC power supply cord into outlet.
4. Program DPC.
a. Press Timer/Clock pad twice.
b. Press Start button once.
c. Press Micro Power pad once.
5. Program oven at High power for 1 minute and press [Start]
button.
a. After approximately 3 seconds, oven stops operating.
b. During
oven
operation,
the
input
current
is
approximately 0.4A.
INPUT CURRENT
FAILURE CODE
Unplug CN701
0.4A
Oven stops in 3
seconds after started.
If both a and b check OK, the Inverter Power Supply (U) can be
determined to be OK.
7.6. Temperature thermistor
These sensor monitors the heat produced by the heater circuit
and maintains the magnetron temperature which user had
selected. Normal room temperature 10°C to 30°C, the reading
across the temperature thermistor should be as follows.
TEMP
MAGNETRON
THERMISTOR
STEAM HEATER
THERMISTOR
OVEN
THERMISTOR
100°C
30-60K
Ω
10-20K
Ω
10-20K
Ω
25°C
700K-1.5M
Ω
100K-300K
Ω
100K-300K
Ω
If the resistance reading is out of the range stated here, the
thermistor is detective and must be replaced.
7.7. IR sensor
To test if IR sensor is ok by doing the following procedures.
Test
1. Program DPC.
a. Press Timer/Clock pad twice.
b. Press Start pad once.
c. Press Micro Power pad once.
2. Press Stop/Reset pad twice, and colon appears on the
display.
3. Open the door, then keep pressing Start
pad for more
than 2 seconds until buzzer beeps.
4. Remain door opening and press Start
pad twice, then
"°C" will be shown on the display.
5. Close the door.
6. Press Start pad, IR sensor will swing. After 6 seconds, it
will stop and show max and minimum temperature readings
of 8 eyes IR sensor on display.
7. If the reading is within the limited range of oven
temperature, and all above is ok, you may decide IR sensor
functions properly.
8. Press Stop/Reset pad to finish the test.
24
NN-CS599S
Summary of Contents for NN-CS599S
Page 2: ...2 NN CS599S ...
Page 3: ...3 NN CS599S ...
Page 5: ...1 FEATURE CHART 2 CONTROL PANEL 5 NN CS599S ...
Page 6: ...3 SCHEMATIC DIAGRAM 6 NN CS599S ...
Page 32: ...10 EXPLODED VIEW AND PARTS LIST 10 1 EXPLODED VIEW 32 NN CS599S ...
Page 40: ...11 DIGITAL PROGRAMMER CIRCUIT 11 1 SCHEMATIC DIAGRAM 40 NN CS599S ...
Page 41: ...41 NN CS599S ...