6.7. Door assembly
1. Remove left and right door key springs from door arm with
plier.
NOTE:
Support door before removing door springs.
To remove door C and door A (U)
•
Insert flat blade screwdriver to release hinge pin
from left hinge.
•
Release catch hooks between door C and door A, to
detach the door C.
Release catch hooks.
NOTE:
After replacement of the defective component parts
of the door, reassemble it properly and adjustment
so as to prevent an excessive microwave leakage.
Adjustment of the door assembly(Refer page 25).
2. When mounting the door to the oven, be sure to adjust the
door parallel to the cavity front plate by moving hinges back
or forward.
3. Adjust so that the upper portion of the door will touch firmly
to the oven cavity front plate, without pushing the door.
If the door assembly is not mounted properly, microwave
power may leak from the clearance between the door and
oven.
4. Be sure the gap between left or right portion of door
assembly and cavity front plate will be 0.6±0.3mm.
5. Always perform the microwave leakage measurement test
after installation and adjustment of door assembly.