13
■ Make sure to ask a service person for installation. Do not install by yourself.
■ If the installation, test run and inspection of the washing machine are not carried out following this installation
method, Panasonic will not be liable for any accident or damage caused.
4. Connect the water tap adaptor and water supply hose.
1
Connect the water tap
adaptor to the water faucet.
1
Turn part A to the left until approx.
4 mm of the thread becomes
visible.
2
Loosen the 4 screws.
3
Connect to the faucet and tighten
the screws.
4
Turn part A to the right and tighten
securely. (To prevent water
leakage)
2
Connect the water
supply hose to the water
tap adaptor.
Insert the hose into the adaptor while
pushing down the lever, and hook
the claw of the lever on the flange of
the adaptor.
3
Connect the water
supply hose to the water
supply valve screw.
1
Hold the elbow and tighten the nut.
2
Check that the elbow is not loose.
Water faucet
Water supply hose
Water tap adaptor
CAUTION
● Tighten the nut firmly.
● Do not twist, squash, modify
or cut the hose.
Part A
Flange
Thread
Lever
Claw
Screw
5. Connect the power plug and grounding wire.
● Ask a service person to do the grounding work.
● In case of a 2-pin power cord, establish a ground.
6. Check that the washing machine is level.
■
Check the balance state using a plummet:
1
Take upper edge of the body as the base. From this position,
release the string to make it vertical to the ground.
2
Take lower edge of the body as the base. Measure the
distance from the edge to the string. The distance must be
less than 10 mm to the left, to the right, to the front, and to
the back of the machine.
■
If the washing machine wobbles
3
Turn to
the right to
tighten.
1
Turn the adjustable leg
knob to the left to loosen.
2
Turn the
adjustable leg
to eliminate
wobble.
To lower
To raise
Body
Upper
edge
String
Plummet
Less than 10 mm
Lower
edge
7. Perform a trial operation.
● Check that there is no water leakage, abnormal sounds or error display.
Elbow
Water supply hose
Nut
Water supply
valve screw
Installation