No. SX-DSV02829 -
190-
Class 9: Linear-related
Class
No.
Title
Unit
Range
Size
[byte]
Attribute
Related
control
mode
Reference
9
20
Magnet pole
detection scheme
selection
―
0–3
2
Select the detection scheme for magnet
pole position.
R
All
4-7-3-1
4-7-3-2
4-7-3-3
21
CS phase setup
Electrical
angle
(
°
)
0–360
2
Set up the phase difference between the
induced voltage of the motor and the CS
signal.
R
All
4-7-3-1
22
Magnet pole
position estimation
torque command
time
ms
0–200
2
Set up the command torque time for
Magnet pole position estimation.
B
All
4-7-3-2
23
Magnet pole
position estimation
command torque
%
0–300
2
Set up the command torque for magnet
pole position estimation.
B
All
4-7-3-2
24
Magnet pole
position estimation
zero travel pulse
width setup
pulse
0–32767
2
Set up the zero travel pulse width for
magnet pole position estimation.
B
All
4-7-3-2
25
Number of pulses
for magnet pole
position estimation
motor stop
judgment
pulse
0–32767
2
Set up the number of pulses for motor stop
judgment for magnet pole position
estimation.
B
All
4-7-3-2
26
Time for magnet
pole position
estimation motor
stop judgment
ms
0–32767
2
Set up the motor stop judgment time for
magnet pole position estimation.
B
All
4-7-3-2
27
Time for magnet
pole position
estimation motor
stop limitation
ms
0–32767
2
Set up the motor stop limitation time for
magnet pole position estimation.
B
All
4-7-3-2
28
Magnet pole
position estimation
torque command
filter
0.01ms
0–2500
2
Set up the time constant for filter
respective to the command torque for
magnet pole position estimation.
B
All
4-7-3-2
29
Overload protection
timing
characteristic
selection
―
0–7
2
Setup value 0: According to standard
specifications
Select the overload protection timing
characteristic from eight types of
characteristics.
R
All
7-2
30
Number of pulses
per magnet pole
pulse
0–327670000
4
Linear motor information can be set in
pulses, which is valid for linear-type
settings. This parameter cannot be used at
the same time with Pr 9.02 (Magnet pole
pitch). Use either of these parameters for
setting.
R
All
4-7-1-1
4-7-4
31
For manufacturer’s
use
―
―
2
Always set to 0.
―
―
―
32
For manufacturer’s
use
―
―
2
Always set to 0.
―
―
―
33
For manufacturer’s
use
―
―
2
Always set to 100.
―
―
―
34
For manufacturer’s
use
―
―
2
Always set to 0.
―
―
―
R1.00