Setting up the main unit
• Setting the
Manual output select
switches
• ON ........ In this position, the Melody Week is
manually switched to produce
G)
Melody Output and/or
®
Control
Output (only either one is possible).
•AUTO ... In this position, the Melody Week
produces an output according to a
program (Normally, set the switch to
this position}.
(CH01)
ON ...
8
AUTO,._
OFF,._
(CH02)
ON ...
8
AUTO ...
OFF ...
•OFF ...... In this position, the Melody Output and
the Control Output are manually
brought to a stop.
G)
To produce the Melody Output when the
switch is set to ON
position:
(The Melody Output is produced only once.)
Press the
button on the
Melody select
main unit to select the melody No.
Melody No. display Melody No. display
for channel 2
forchannel1
-�·-··--'i.===::::::;-i
: ,::,-.:
I
•11
I
:
,::�,:
I
11� I
....... .1 .......... .1
The melody No. can be displayed in a range of "1
to 8".
When "-" is indicated, the Melody Output is not
produced.
Melody can be selected for each channel.
00
��
G) Each time
l
�r!:���.
is
§ §
"1 to 8"
and"-" are
(g)
To produce the Control Output when the
Manual output select
switch is set to the ON
position:
Set the
Control Output
to the ON position.
The Control Output is produced until the
Manual output
tmmmlswitch is changed over to the AUTO or the OFF
position, and an output lamp comes on.
The Control Output can be set for each channel.
-23-
displayed
-t.r.s;ifROLOUTPUT(ON/OFF)J
in turn.
®
• Interrupt input
By connecting a push button (non-voltage contact) to the interrupt input terminal, (Dthe
Melody Output and/or@the Control Output can be externally produced (only either one is
possible).
The Melody Output is produced only once since the interrupt input is triggered.
The Control Output will remain on as long as the interrupt input signal is present.
Switch (non-voltage contact)
Interrupt input
G)
To produce the Melody Output at the time of
Interrupt input:
(The same Melody Output can be produced continuously
from 1 to 9 times by means of a single interrupt input.)
Melody select
r,
��r::
o
t
=:lect the mel
o
dy b�:,
on on
the mai
n
The melody No. can be displayed in a range of "1
to 8".
When the melody No. is displayed, the Ringing
Times "1" is displayed.
When "-" is indicated, the Melody Output is not
produced.
Select the number of melody output times
using the
button
The melody No. can be selected in a range of "1
to 9". to 8".
(g)
To produce the Control Output at the time of
Interrupt input:
Set the
to the ON position.
Control Output
The Control Output is produced during Interrupt input
The Control Output is carried out for channel 2.
• Sound volume adjustment
Melody No. No. of output times
___
{
____ �
: -,::I:
I
1
1
I
..... :1�::,:
:.��: ........ .!
G) Each time a switch
is pressed, "1 to 8"
and"-" are
displayed in turn.
Sound volume adjustment
of microphone
�
Sound volume adjustment of
Sound volume adjustment of
main unit built- in speaker
expanded external speaker
I
/
Sound volume
/ adjustment of
INTERNAL
EXERNAL
MELODY/
melody signal
MICROPHONE
SPEAKER
SPEAKER
SIGNAL
output
r •
tf tf
Ot
(Turn right volume up and left to volume down.)
-24-