background image

- 9 -

PARTS LIST 

(MOTOR FAN ASSEMBLY)

1

2

3

4

5

6

7

8

9

EXPLODED VIEW 

(MOTOR FAN ASSEMBLY)

Ref. No.

Part Name & Description

Part No.

Quantity

Remarks

1

Fan Case

AMC53F-AVØØU

1

2

Nut

AMC33F-ACØØU

1

3

Washer (a)

AMC62F-AVØØU

1

4

Fan

AC98FRFZØØ

1

5

Washer (b)

AC62FRFZØØ

1

6

Spacer

AC6ØFRFZØØ

1

7

Brush Assembly

AC27FRFZØØ

1(Set)

8

Bracket

AMCØ2D-V3ØØU

2

9

Screws

AMC4ØD-V3ØØU

4

LOWER PLATE REMOVAL/INSTALLATION

Removal

1.

Place the handle in upright position.

2.

Turn the vacuum cleaner over exposing the underside.  Release the lower

plate by pressing the two (2) latches that secure it inward, (

Fig 1)

.

3.

Separate the lower plate from the vacuum.

Installation

1.

Hook the front of the lower plate into the slots on the front of the nozzle housing.

Press the lower plate down into place.

2.

Fasten the lower plate by pushing the two (2) latches outward.

NOTE:  For general servicing, it is necessary to eliminate pinching of any

wire during reassembly.  After servicing any electrical component or

electrical enclosure, the unit should be reassembled and checked

for dielectric breakdown or current leakage.

(Fig. 1)

AGITATOR ASSEMBLY REMOVAL/INSTALLATION

Removal

The brushes are replaceable separately.  When the brushes need replacing, the

agitator assembly will have to be removed.

1.

Remove the lower plate as outlined in the LOWER PLATE REMOVAL/

INSTALLATION section.

2.

Carefully lift up on the agitator assembly until it clears both sides of the nozzle

housing, (

Fig. 2

).

3.

Remove the belt from the motor shaft by sliding it off between the end of the

shaft and the nozzle housing, (

Fig. 3

).

NOTE:  The two (2) end caps may come off as you lift the agitator assembly

out.  Look at the exploded view of the agitator  assembly in the B Block

section for correct assembly of parts.  The end caps can be reused.

Installation

1.

Place the belt around the motor shaft, (

Fig. 3

).

2.

Start the new agitator assembly back into the nozzle housing by placing the 

side opposite the belt partially into the slot.  This will hold the agitator in place, 

and leave both hands free to place enough tension on the belt to allow that side 

of the agitator to return to the nozzle housing slot.

3.

Place the belt around the agitator pulley on the agitator assembly.             

Note:  There is a place for the belt to fit on one end of the agitator 

assembly only.  This is the agitator pulley.

4.

Use both hands to pull the belt tight, (

Fig. 4

), and slide the agitator

assembly firmly into the slots on each end of the nozzle housing.

5.

Rotate the agitator assembly by hand to insure nothing rubs and to 

check for correct assembly.

6.

Replace the lower plate as outlined in the LOWER PLATE REMOVAL/

INSTALLATION section.

(Fig. 2)

(Fig. 3)

(Fig. 4)

- 12 -

Summary of Contents for MCV225 - COMMERCIAL VACUUM

Page 1: ...DIVISION OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA All rights reserved Unauthorized copying and distribution is a violation of law Commercial Vacuum Cleaner Model MC V225 Power Source AC 120V 60 Hz Power Consumption 10 0 Amps Cord Length 50 Ft Motor Protector Yes Height Adjust 4 Position Weight 17 lbs ...

Page 2: ......

Page 3: ...OTE Do not pinch any wires during reassembly After servicing any electrical component or electrical enclosure the unit should be reassembled and checked for dielectric breakdown or current leakage M BLK Motor Housing Fuse BLK BLK BLK BLK BLK BLK GRN WHT WHT ...

Page 4: ......

Page 5: ... 5 EXPLODED VIEW NOZZLE HOUSING BLOCK A ...

Page 6: ......

Page 7: ... 7 EXPLODED VIEW BODY MOTOR HOUSING AND MOTOR BLOCK C ...

Page 8: ......

Page 9: ...EMBLY Ref No Part Name Description Part No Quantity Remarks 1 Fan Case AMC53F AVØØU 1 2 Nut AMC33F ACØØU 1 3 Washer a AMC62F AVØØU 1 4 Fan AC98FRFZØØ 1 5 Washer b AC62FRFZØØ 1 6 Spacer AC6ØFRFZØØ 1 7 Brush Assembly AC27FRFZØØ 1 Set 8 Bracket AMCØ2D V3ØØU 2 9 Screws AMC4ØD V3ØØU 4 ...

Page 10: ......

Page 11: ...er Pull off Lower Plate Release latches and tilt off Agitator Assembly Belt Lift out with end caps Nozzle Housing Pull off Motor Case Remove four screws and pull off On Off Switch Dust Cover Pull off Power Cord Switch Cover Remove two screws and pull off Nozzle Housing Lower Plate Release latches and tilt off Agitator Assembly Belt Lift out with end caps Height Adjust Assembly Remove three 3 screw...

Page 12: ......

Page 13: ... Removal 1 Follow all of the instructions outlined in the agitator assembly removal section Installation 1 Place the new belt around the motor shaft and follow the instructions in the agitator assembly replacement section ...

Page 14: ......

Page 15: ...by prying or cutting remove the wire connectors and wire tie if present 3 Remove the ON OFF switch for ON OFF switch replacement by depressing the switch retaining tabs while pushing up out of the dust compartment at the same time 4 Pull the power cord out of the dust compartment for power cord replacement Continued on p 16 POWER CORD ON OFF SWITCH REPLACEMENT SWITCH COVER AREA WIRING MANAGEMENT F...

Page 16: ......

Page 17: ...he brushes for the approximate dimension as shown in Fig 15 Removal 1 Remove the dust cover by grasping the top near the On Off switch and pulling sharply out toward you 2 Remove the lower plate agitator assembly belt and the nozzle housing as instructed in the respective removal sections 3 Turn the vacuum over to the front side 4 Remove the four 4 screws from the motor case and then remove the mo...

Page 18: ......

Page 19: ...er or carbon brush worn out Adjust or replace ON OFF switch continuity Remove switch cover and check If there is no continuity between continuity across switch terminals both terminals ON OFF switch must be defective Dust bag Check quantity of dust accumulated in Replace dust bag if full Paper dust bag Empty dust bag Cloth Filters Check for dirty filter Clean and or Change Filters Nozzle hose Remo...

Page 20: ......

Reviews: