- 7 -
- 14 -
EXPLODED VIEW
(BODY, MOTOR HOUSING, AND MOTOR)… BLOCK
C
Removal
1.
Remove the lower plate as outlined in the LOWER
PLATE REMOVAL/INSTALLATION section.
2.
Remove the belt and agitator assembly as outlined in
the respective sections.
3.
Remove the nozzle hose by pulling up to remove it from
the nozzle housing. Pull the nozzle hose out of the back of
the nozzle housing.
4.
Insert a flat blade screwdriver between the nozzle
housing and the plastic shaft, pry out the plastic shaft as illustrated,
(Fig.
6)
.
5.
Remove the nozzle housing as illustrated,
(Fig 7)
.
6.
Remove the window and height adjust assembly.
NOTE: If the motor case is removed, DO NOT turn vacuum over as
the motor may fall out.
Installation
1.
Install the window and height adjust assembly in the new nozzle.
2.
Fit the nozzle from the motor shaft side first, and rotate it into place on
the dust container as illustrated, (
Fig. 8
).
3.
Slide the plastic shaft through the nozzle housing and into the dust container. Make sure that the slot on the bottom of
the plastic shaft is down and fitted onto the projection,
(Fig. 9)
.
4.
Reassemble the nozzle hose by inserting it into the nozzle. Push the nozzle hose down into the slot in the nozzle
housing.
5.
Install the belt, agitator assembly, and the lower plate according to the respective instructions.
NOZZLE HOUSING REPLACEMENT
Plastic
Shaft
Nozzle
Housing
(Fig. 7)
(Fig. 8)
Flat-head
Screwdriver
(Fig. 6)
Plastic Shaft
Nozzle
Housing
Projection
(Fig. 9)