background image

LC2H

73

Explanation of operation

1. Counting takes place when the count 
input signal is ON.
2. Counting resumes again when the 
count value reaches 99999999 (full scale 
value) and then returns to “0” with a new 
count input.
3. No measurement takes place when a 
reset is input.
1) When reset is ON, resetting takes place 
and the count becomes “0”.
2) Press the front reset button when you 
want to reset manually (only panel instal-
lation type).

Note) Be aware that battery life will decrease if the 

count input or reset input are left ON.

Note) 

Count becomes “1” when the reset input is turned OFF while the count signal is being input.

Reset input

Count value

Count input

0

1

0

0

1

1

99999999

Cautions for use

1. Non-voltage input type
For both panel mounting and PC board 
mounting types

1) Never apply voltage to the non-voltage 
input type. This will damage the internal 
elements. Also, since there is a possibility 
of erroneous operation, do not connect in 
parallel the inputs of a non-voltage input 
type and another counter from a single in-
put signal.
2) Since the current flow is very small from 
the count input and reset input terminals 
(

1

 and 

3

 on the panel mounting type 

and terminals 

e

 to 

t

 and 

S

 to 

F

 on the 

PC board mounting type) please use re-
lays and switches with high contact reli-
ability.
3) When inputting with an open collector 
of a transistor, use a transistor for small 
signals in which ICBO is 1 µA or less and 
always input with no voltage.
4) When wiring, try to keep all the input 
lines to the count and reset inputs as short 
as possible and avoid running them to-
gether with high voltage and power trans-
mission lines or in a power conduit. Also, 
malfunctions might occur if the floating ca-
pacitance of these wires exceeds 500 pF 
(10 m 

32.808 ft.

 for parallel wires of 2 

mm

2

). When using 2 kHz mode, use with 

a wiring floating capacitance of 120 pF (3 

9.843 ft.

 for parallel wires of 2 mm

2

). In 

particular, when using shielded wiring, be 
careful of the capacitance between wires.

PC board mounting type

1) For external power supply use manga-
nese dioxide or lithium batteries (CR type: 
3V).
2) Always reset after external power is ap-
plied and confirm that the display reads 
“0”.
3) Make the wiring from the battery to the 
counter unit as short as absolutely possi-
ble. Also, be careful of polarity.
4) Calculate battery life with the following 
formula.
    t = A/I

t: battery life [h]
I: LC2H current consumption [mA]
A: battery capacity until minimum 

operation voltage is reached 
[mAh]

5) Hand solder to the lead terminal. Do not 
dip solder. With the tip of the soldering iron 
at 300°C 

572°F

 perform soldering within 3 

seconds (for 30 to 60 W soldering iron).

2. Voltage input type

1) Be aware that applying more than 30 V 

DC to count input terminals 

1

 and 

2

, and 

reset input terminals 

3

 and 

4

 will cause 

damage to the internal elements.
2) For external resetting use H level (ap-
plication of 4.5 to 30 V DC) between reset 
terminals 

3

 and 

4

 of the rear terminals. 

In this case, c to terminal 

3

 and 

– to terminal 

4

. This is the valid polarity; 

therefore, the counter will not work if re-
versed.
3) When wiring, try to keep all the input 
lines to the count and reset inputs as short 
as possible and avoid running them to-
gether with high voltage and power trans-
mission lines or in a power conduit. Also, 
malfunctions might occur if the floating ca-
pacitance of these wires exceeds 500 pF 
(10 m 

32.808 ft.

 for parallel wires of 2 

mm

2

). 

3. Free voltage input type

1) Use count input terminals 

1

 and 

2

 for 

free voltage input and reset terminals 

3

 

and 

4

 for non-voltage input.

2) Be aware that the application of voltage 
that exceeds the voltage range of the H 
level to the count input terminal, and the 
application of voltage to the reset input 
terminal, can cause damage to the inter-
nal elements.

2. Backlight type

Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight.

2.

2

 and 

4

. (The input and reset circuits are functionally insulated.)

3. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage 

Q

 50 V, leakage current < 1 µA)

4. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input 

terminal, can cause damage to the internal elements.

Voltage input type

Backlight connection

Contact input

Transistor input

NPN transistor

PNP transistor

Reset

input

Count

input

1

2

3

4

5

6

0V

0V

Reset

input

Count

input

1

2

3

4

+V

+V

5

6

1

2

3

4

5

6

Reset

input

Count

input

+V

+V

1

2

3

4

Green

Red

24V DC

24V DC

5

6

1

2

3

4

5

6

LC2H.fm  Seite 73  Samstag, 23. März 2002  4:15 16

02/2003

Summary of Contents for LC2H preset

Page 1: ... Non voltage input method 2 Voltage input method 3 Free voltage input method 10 BacklightType Added to Series and Now 2 color Switchable green red Easy viewing even in dark places and switchable between green and red Volt age input type 11 Conforms to Safety Regulations 8 7mm 343inch 8 digits Product chart Product types 1 Panel mounting type 1 One touch installation type 1 Standard type Note Pleas...

Page 2: ...ed 2 kHz 30 Hz Switchable by switch 30 Hz Note 2 Count input Min input signal width ON OFF 1 1 0 25 ms 16 7 ms Switchable by switch 16 7 ms Input method signal Non voltage input using contactsoropencollector connection High level 4 5 to 30 V DC Low level 0 to 2 V DC High level 24 to 240 V AC DC Low level 0 to 2 4 V AC DC Input impedance When shorted Max 10 k When open Max 750 k Approx 4 7 k Residu...

Page 3: ...hock resistance Functional Min 98 m s2 4 times on 3 axes Destructive Min 294 m s2 5 times on 3 axes Operation temperature 10 to 55 C 14 to 131 F without frost or dew Storage temperature 25 to 65 C 13 to 149 F without frost or dew Ambient humidity 35 to 85 RH Part names 1 Front reset button Thisbuttonresetsthecountvalue Itdoes not work when the lock switch is ON Be aware that battery life will decr...

Page 4: ...ded Panel 1 to 4 5mm 039 to 177inch thickness Panel cut out dimensions The standard panel cut out is shown below Use the mounting bracket ATH3803 and the rubber packing ATH3804 Only mounting bracket installation type When installing repeatedly sealed installation Only mounting bracket installation type Notes 1 Suitable installation panel thickness is 1 to 4 5 mm 039 to 177 inch 2 Waterproofingwill...

Page 5: ... use the following as a guide for which transistors Tr to use for inputting Collector withstand voltageQ 50 V leakage current 1 µA Notes 1 2 and 4 The input and reset circuits are functionally insulated 2 When using transistor Tr input use the right as a guide Collector withstand voltage Q 50 V leakage current 1 µA 3 Be aware that the application of voltage that exceeds the voltage range of the H ...

Page 6: ...y to the counter unit as short as absolutely possi ble Also be careful of polarity 4 Calculate battery life with the following formula t A I t battery life h I LC2H current consumption mA A battery capacity until minimum operation voltage is reached mAh 5 Handsoldertotheleadterminal Donot dipsolder Withthetipofthesolderingiron at300 C572 Fperformsolderingwithin3 seconds for 30 to 60 W soldering ir...

Page 7: ...d to prevent water from entering theunitandarubbergasketisprovidedto prevent water from entering the gap be tweentheunitandthepanelcutout There mustbesufficientpressureappliedtothe rubbergaskettopreventwaterfromenter ing Be sure to use the installation rein forcement screws when installing the frame ATH3803 Note The one touch installation type is not waterproof 8 Do not use in the following enviro...

Page 8: ...the front panel by replacing it with this black panel cover The counter comes with an ash gray panel cover as standard 2 Lithium battery 3 V Part No ATH3802 Comes packaged with the LC2H exclud ing the PC board mounting type 3 Installation parts Mounting bracket suitable for installa tion frame type Part No ATH3803 Packaged with LC2H panel mounting type installation frame type Rubber gasket suitabl...

Reviews: