background image

                                                             

  

      

 

                                                                                                        

ELECTRICAL CONNECTION 

 

            Manufacturer:

           

Terazidere Mah.60.Yil Cad.No:5/3 

           34035 Bayrampasa/ISTANBUL/TURKEY

                             TEL: 0 212 501 48 63

                                               FAX: 0 212 501 48 83 
                                               

Email: 

[email protected]

                        MODEL OP-CN4

      

UNIVERSAL

 

                        

INCREMENTAL 

           

COUNTER

 

                                                                                                        

   

 Ver 2.0E

   USER GUIDE

     

                              

WARNING!

READ CAREFULLY BEFORE POWER ON

1.

Complete electrical connections according to the 

                             schematic at the last page.

2.

Check Supply Voltage 220V (or 24V optional) AC, or DC, due to 

                            Specifications  on  the equipment.

3.

Use only shielded cable for sensors.

4.

Keep away the equipment from direct heat source.

5.

MODEL OP-CN4  is not suitable for outdoor use.

6.

Keep away the equipment from water or other liquid 

                  drains.

7.

Do not open, modify or replace any component in the 
equipment, If any problem occurs please contact an authorised 
OPKON technical service or OPKON directly.                                               

                  ELECTRICAL SPECIFICATIONS:

Microcontroller based
A /B /Z(Reset)-4 X Counter mode
200 kHz Max. counting frequency
2 X Relays output
1 X SSR output
Incremental or absolute positioning mode
Holding on the last value in memory
10 X Output modes
Offset calibration
Password to protect menus

Power Supply

:220V ± % 20 (or 24V optional)

 

 ,50 Hz 

Power Consumption

                  :<4 VA (protected by fuse 50mA)

Sensor supply voltage

                  :+5V or +12VDC (selectable by jumper)

Sensor supply current

                  :Max.100mA(no fuse)

Relays max. ratings

                  :Relay1

1xNO+NC  8A,230V AC 

 

 Relay2

1xNO+NC  8A,230V AC

SSR output

:5V DC (non-isolated)

MECHANICAL SPECIFICATIONS:

Dimensions

                  :72x72x90 mm

Panel cut dimensions                                     :67x67mm
Body

                                    :ABS plastic

                  Working temperature                                     :0-60 ºC

                  

Storage temperature                                     :-10ºC …+80ºC

                    

Humidity                                                          :

<%90 RH

  

Reviews: