background image

LC2H

69

2) Installation frame type

1

 Standard type

Note) Please ask us about types without front resetting.

No. digits

Counting speed

Front reset

Input method

Part No.

8 digits

2 kHz/30 Hz switchable

Yes

Non-voltage input type

LC2H-F-2KK

Voltage input type (4.5 to 30 V DC)

LC2H-F-DL-2KK

30 Hz

Free voltage input type (24 to 240 V AC/DC)

LC2H-F-FV-30

2

 Backlight type

2. PC board mounting type

Specifications

1. Panel mounting type

Notes) 1. The value given for battery life is calculated based on continuous operation (count input signal ON/OFF = 1:1), therefore, this value is not guaranteed. 

Also, battery life is decreased 30% when operation is continuous with 2 kHz count inputting in 2 kHz mode.

2. Operation is at 25 Hz when using 24 V AC.
3. Only for installation frame type.

No. digits

Counting speed

Front reset

Input method

Part No.

8 digits

2 kHz/30 Hz switchable

Yes

Voltage input type (4.5 to 30 V DC)

LC2H-F-DL-2KK-B

No. digits

Counting speed

Front reset

Input method

Part No.

8 digits

2 kHz

No

Non-voltage input type

LC2H-C-2K-N

30 Hz

LC2H-C-30-N

Type

Standard type

Backlight type

Standard type

Item

Non-voltage input

Voltage input

Free voltage type

No. digits

8 digits

External power supply

Not required (built-in battery)

Max. counting speed

2 kHz/30 Hz (Switchable by switch)

30 Hz (Note 2)

Count 
input

Min. input signal width
(ON: OFF = 1:1)

0.25 ms/16.7 ms (Switchable by switch)

16.7 ms

Input method (signal)

Non-voltage input using 
contacts or open collector 
connection

High level: 4.5 to 30 V DC
Low level: 0 to 2 V DC

High level: 
    24 to 240 V AC/DC
Low level: 
    0 to 2.4 V AC/DC

Input impedance

When shorted: 
    Max. 10 k
When open: 
    Max. 750 k

Approx. 4.7 k

Residual voltage

Max. 0.5 V

Reset 
input

Min. input signal width

200 ms

Input method (signal)

Non-voltage input using 
contacts or open collector 
connection

High level: 4.5 to 30 V DC
Low level: 0 to 2 V DC

Non-voltage input using 
contacts or open collector 
connection

Input impedance

When shorted: 
    Max. 10 k
When open: 
    Max. 750 k

Appox. 4.7 k

When shorted: 
    Max. 10 k
When open: 
    Max. 750 k

Residual voltage

Max 0.5 V

Max. 0.5 V

Display method

7-segment LCD

 7-segment LCD
 With green/red backlight

7-segment LCD

Breakdown voltage (initial)

Between charged and uncharged parts: 1,000 V AC for 1 minute.

Between charged and 
uncharged parts: 2,000 V 
AC for 1 minute.

Insulation resistance (initial)

Min. 100 M  (measured at 500 V DC) Measurement location same as for break down voltage.

Backlight power

24 V DC (±10%)

Protective construction (Note 3)

IEC Standard IP66 (only panel front: when using rubber gasket)

Accessories (Note 3)

Rubber gasket, mounting bracket

Battery life

7 years (at 25°C 

77°F

) Note 1

6 years (at 25°C 

77°F

)

LC2H.fm  Seite 69  Samstag, 23. März 2002  4:15 16

02/2003

Summary of Contents for LC2H preset

Page 1: ... Non voltage input method 2 Voltage input method 3 Free voltage input method 10 BacklightType Added to Series and Now 2 color Switchable green red Easy viewing even in dark places and switchable between green and red Volt age input type 11 Conforms to Safety Regulations 8 7mm 343inch 8 digits Product chart Product types 1 Panel mounting type 1 One touch installation type 1 Standard type Note Pleas...

Page 2: ...ed 2 kHz 30 Hz Switchable by switch 30 Hz Note 2 Count input Min input signal width ON OFF 1 1 0 25 ms 16 7 ms Switchable by switch 16 7 ms Input method signal Non voltage input using contactsoropencollector connection High level 4 5 to 30 V DC Low level 0 to 2 V DC High level 24 to 240 V AC DC Low level 0 to 2 4 V AC DC Input impedance When shorted Max 10 k When open Max 750 k Approx 4 7 k Residu...

Page 3: ...hock resistance Functional Min 98 m s2 4 times on 3 axes Destructive Min 294 m s2 5 times on 3 axes Operation temperature 10 to 55 C 14 to 131 F without frost or dew Storage temperature 25 to 65 C 13 to 149 F without frost or dew Ambient humidity 35 to 85 RH Part names 1 Front reset button Thisbuttonresetsthecountvalue Itdoes not work when the lock switch is ON Be aware that battery life will decr...

Page 4: ...ded Panel 1 to 4 5mm 039 to 177inch thickness Panel cut out dimensions The standard panel cut out is shown below Use the mounting bracket ATH3803 and the rubber packing ATH3804 Only mounting bracket installation type When installing repeatedly sealed installation Only mounting bracket installation type Notes 1 Suitable installation panel thickness is 1 to 4 5 mm 039 to 177 inch 2 Waterproofingwill...

Page 5: ... use the following as a guide for which transistors Tr to use for inputting Collector withstand voltageQ 50 V leakage current 1 µA Notes 1 2 and 4 The input and reset circuits are functionally insulated 2 When using transistor Tr input use the right as a guide Collector withstand voltage Q 50 V leakage current 1 µA 3 Be aware that the application of voltage that exceeds the voltage range of the H ...

Page 6: ...y to the counter unit as short as absolutely possi ble Also be careful of polarity 4 Calculate battery life with the following formula t A I t battery life h I LC2H current consumption mA A battery capacity until minimum operation voltage is reached mAh 5 Handsoldertotheleadterminal Donot dipsolder Withthetipofthesolderingiron at300 C572 Fperformsolderingwithin3 seconds for 30 to 60 W soldering ir...

Page 7: ...d to prevent water from entering theunitandarubbergasketisprovidedto prevent water from entering the gap be tweentheunitandthepanelcutout There mustbesufficientpressureappliedtothe rubbergaskettopreventwaterfromenter ing Be sure to use the installation rein forcement screws when installing the frame ATH3803 Note The one touch installation type is not waterproof 8 Do not use in the following enviro...

Page 8: ...the front panel by replacing it with this black panel cover The counter comes with an ash gray panel cover as standard 2 Lithium battery 3 V Part No ATH3802 Comes packaged with the LC2H exclud ing the PC board mounting type 3 Installation parts Mounting bracket suitable for installa tion frame type Part No ATH3803 Packaged with LC2H panel mounting type installation frame type Rubber gasket suitabl...

Reviews: