LC2H

74

3) Since the current flow is very small from 
reset input terminal 

3

, please use relays 

and switches with high contact reliability.
4) When inputting a reset with an open 
collector of a transistor, use a transistor 
for small signals in which ICBO is 1 µA or 
less and always input with no voltage.
5) To reset externally, short reset input ter-
minals 

3

 and 

4

 on the rear.

6) Input uses a high impedance circuit; 
therefore, erroneous operation may occur 
if the influence of induction voltage is 
present. If you plan to use wiring for the in-
put signal that is 10 m or longer (wire ca-
pacitance 120 pF/m at normal 
temperature), we recommend the use of a 
CR filter or the connection of a bleeder re-
sistor. 

4. How to reset multiple panel mount-
ing type counters all at once (input is 
the same for count)
Non-voltage input type

Notes) 1. Use the following as a guide for choosing 

transistors used for input (Tr).
Leakage current < 1 µA

2. Use as small a diode (D) as possible in the 

forward voltage so that the voltage between 
terminals 3 and 4 during reset input meets 
the standard value (0.5 V).
( At IF = 20 µA, forward voltage 0.1 and 
higher.)

Voltage input type

Note) Make sure that H (reset ON) level is at least 4.5 

V.

5. Backlight luminance

To prevent varying luminance among 
backlights when using multiple Backlight 
types, please use the same backlight 
power supply.

6. Insulation sheet

Before using a panel mounting type, 
please pull and remove the insulation 
sheet from the side of the product in the 
direction of the arrow.
In consideration that the product might be 
stored for long periods without being 
used, an insulation sheet is inserted be-
fore shipping. Remove the insulation 
sheet and press the front reset button.

One-touch installation type

Installation frame type

7. Waterproof construction (Installa-
tion frame type)

The operation part of the panel installa-
tion type (Installation frame type) is con-
structed to prevent water from entering 
the unit and a rubber gasket is provided to 
prevent water from entering the gap be-
tween the unit and the panel cutout. There 
must be sufficient pressure applied to the 
rubber gasket to prevent water from enter-
ing. Be sure to use the installation rein-
forcement screws when installing the 
frame (ATH3803).

Note) The one-touch installation type is not 

waterproof.

8. Do not use in the following environ-
ments

1) In places where the temperature 
changes drastically.
2) In places where humidity is high and 
there is the possibility of dew. (When dew 
forms the display may vanish and other 
display errors may occur.)

9. Conditions of use

1) Do not use in places where there is 
flammable or corrosive gas, lots of dust, 
presence of oil, or where the unit might be 
subject to strong vibrations or shocks.
2) Since the cover is made of polycarbon-
ate resin, do not use in places where the 
unit might come into contact with or be ex-
posed to environments that contain or-

ganic solvents such as methyl alcohol, 
benzene and thinner, or strong alkali sub-
stances such as ammonia and caustic so-
da.

10. Cautions regarding battery replace-
ment

1) Remove wiring before replacing the 
battery. You may be electrocuted if you 
come into contact to a part where high 
voltage is applied.
2) Make sure you are not carrying a static 
electric charge when replacing the bat-
tery.
3) Battery replacement procedure

1

 One-touch installation type

1. Using a tool remove the up/down hook 
of the case. 
2. Pull the unit away from the case.
3. Remove the battery from the side of the 
unit. Do not touch the display or other 
parts.
4. Before inserting wipe clean the surface 
of the battery.
5. Insert the battery with the + and – sides 
in the proper position.
6. After replacing the battery return the 
unit to the case. Verify that the hook of the 
case has properly engaged. 
7. Before using press the reset button on 
the front.

3

or

D

Tr

4

3 4

3 4

D

D

3

or

+V

+V

R
Tr

4

3 4

3 4

3 4

2

2

5

2

Green

Red

5

6

2

6

24V DC

24V DC

Insulation sheet

Reset button

Insulation sheet

Reset button

Frame (ATH3803)

Tool

1

2

1

6

7

3

LC2H.fm  Seite 74  Samstag, 23. März 2002  4:15 16

02/2003

Summary of Contents for LC2H preset

Page 1: ... Non voltage input method 2 Voltage input method 3 Free voltage input method 10 BacklightType Added to Series and Now 2 color Switchable green red Easy viewing even in dark places and switchable between green and red Volt age input type 11 Conforms to Safety Regulations 8 7mm 343inch 8 digits Product chart Product types 1 Panel mounting type 1 One touch installation type 1 Standard type Note Pleas...

Page 2: ...ed 2 kHz 30 Hz Switchable by switch 30 Hz Note 2 Count input Min input signal width ON OFF 1 1 0 25 ms 16 7 ms Switchable by switch 16 7 ms Input method signal Non voltage input using contactsoropencollector connection High level 4 5 to 30 V DC Low level 0 to 2 V DC High level 24 to 240 V AC DC Low level 0 to 2 4 V AC DC Input impedance When shorted Max 10 k When open Max 750 k Approx 4 7 k Residu...

Page 3: ...hock resistance Functional Min 98 m s2 4 times on 3 axes Destructive Min 294 m s2 5 times on 3 axes Operation temperature 10 to 55 C 14 to 131 F without frost or dew Storage temperature 25 to 65 C 13 to 149 F without frost or dew Ambient humidity 35 to 85 RH Part names 1 Front reset button Thisbuttonresetsthecountvalue Itdoes not work when the lock switch is ON Be aware that battery life will decr...

Page 4: ...ded Panel 1 to 4 5mm 039 to 177inch thickness Panel cut out dimensions The standard panel cut out is shown below Use the mounting bracket ATH3803 and the rubber packing ATH3804 Only mounting bracket installation type When installing repeatedly sealed installation Only mounting bracket installation type Notes 1 Suitable installation panel thickness is 1 to 4 5 mm 039 to 177 inch 2 Waterproofingwill...

Page 5: ... use the following as a guide for which transistors Tr to use for inputting Collector withstand voltageQ 50 V leakage current 1 µA Notes 1 2 and 4 The input and reset circuits are functionally insulated 2 When using transistor Tr input use the right as a guide Collector withstand voltage Q 50 V leakage current 1 µA 3 Be aware that the application of voltage that exceeds the voltage range of the H ...

Page 6: ...y to the counter unit as short as absolutely possi ble Also be careful of polarity 4 Calculate battery life with the following formula t A I t battery life h I LC2H current consumption mA A battery capacity until minimum operation voltage is reached mAh 5 Handsoldertotheleadterminal Donot dipsolder Withthetipofthesolderingiron at300 C572 Fperformsolderingwithin3 seconds for 30 to 60 W soldering ir...

Page 7: ...d to prevent water from entering theunitandarubbergasketisprovidedto prevent water from entering the gap be tweentheunitandthepanelcutout There mustbesufficientpressureappliedtothe rubbergaskettopreventwaterfromenter ing Be sure to use the installation rein forcement screws when installing the frame ATH3803 Note The one touch installation type is not waterproof 8 Do not use in the following enviro...

Page 8: ...the front panel by replacing it with this black panel cover The counter comes with an ash gray panel cover as standard 2 Lithium battery 3 V Part No ATH3802 Comes packaged with the LC2H exclud ing the PC board mounting type 3 Installation parts Mounting bracket suitable for installa tion frame type Part No ATH3803 Packaged with LC2H panel mounting type installation frame type Rubber gasket suitabl...

Reviews: