7-6
Maintenance
7.1
Utility Commands
Type “ELOG”, then press [RETURN].
Device error log indications
$ ELOG
DEVICE
ERROR
TIME
1.
CPU
MEM–GET
JUL-14
14:00
PM
2.
CLOCK
JUL-14
14:00
PM
3.
DISK
DATA R/W (xx:yyyy)
JUL-14
14:00
PM
4.
DSP*
SCAN
JUL-14
14:00
PM
5.
DSP*
FIFO
JUL-14
14:00
PM
6. CPU
APPLICATION (x)
JUL-14
14:00
PM
*
= Port number
Note:
Types of errors displayed on the screen and their meanings are as
follows:
Indication
CPU
MEM-GET
CLOCK
DISK
DATA R/W (xx:yyyy)
DSP*
SCAN
DSP*
FIFO
CPU
APPLICATION (x)
Meaning
CPU card software memory acquisition error.
CPU card is short of memory temporarily because
of too much traffic.
Clock access error. Clock IC is out of order.
Check the hardware.
HDD access error. If there is a sector which
often causes errors, check the disk.
xx :
IDE error code
yyyy : read/write error sector number
DSP-SCAN error. DSP is out of order. Check
the hardware.
DSP/FIFO error. During the system is handling
calls, there is wrong with DSP and FIFO memory
temporarily.
Application error. During the system is handling
calls, temporal application error occurs.
x: port number
* = Port number (1 – 12)
Error indications at system startup
Example terminal display when errors are generated