10 THINGS TO DO AFTER REPLACING IC
Cautions:
Since this page is common to each country, it may not apply to some models in your country. The contents below are the
minimum adjustments required for operation.
10.1. Base Unit
Before doing the following adjustment, be sure to do “
PC Setting
” (P.30) in “
The Setting Method of JIG (Base Unit)
”.
IC
Necessary Adjustment
BBIC
Programs for Voice processing, interface for RF and
EEPROM
1. Default batch file: Execute the command “default”.
2. Country version batch file: Execute the command
“TCD240XXrevYY”. (*1)
3. Clock adjustment: Refer to Check Point (F). (*2)
EEPROM
Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Change the address “0000” ofEEPROM to “AA”.
2. Default batch file: Execute the command “default”.
3. Country version batch file: Execute the command
“TCD240XXrevYY”. (*1)
4. Clock adjustment: Refer to Check Point (F). (*2)
FLASH 1
Voice prompt data
(vary depending on country version)
No need to adjust.
FLASH 2
Program
No need to adjust.
Note:
(*1) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in
JIG and PC
(P.30).
(*2) Refer to
Check Point (Base Unit)
(P.25)
10.2. Handset
Before doing the following adjustment, be sure to do “
PC Setting
” (P.38) in “
The Setting Method of JIG (Handset)
”.
IC
Necessary Adjustment
BBIC
Programs for Voice processing, interface for RF and
EEPROM
1. Default batch file: Execute the command “default”.
2. Default batch file (remaining); Execute the command “TCA121
DEFrevYY”. (*3)
(Except for KX-TCA121/122 FX and KX-TCA121/122 RU).
3. Country version batch file: Execute the command
“TCA121XXrevYY”. (*3)
4. Clock adjustment: Refer to Check Point (J). (*4)
5. 1.8 V setting and battery low detection: Refer to Check Point (A),
(H) and (I). (*4)
EEPROM
Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Change the address “0015” ofEEPROM to “55”.
2. Default batch file: Execute the command “default”.
3. Default batch file (remaining): Execute the command
“TCA121DEFrevYY”. (*3)
(Except for KX-TCA121/122 FX and KX-TCA121/122 RU).
4. Country version batch file: Execute the command
“TCA121XXrevYY”. (*3)
5. Clock adjustment: Refer to Check Point (J). (*4)
6. 1.8 V setting and battery low detection: Refer to Check Point (A),
(H) and (I). (*4)
Note:
(*3) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in
JIG and PC
(P.38).
(*4) Refer to
Check Point (Handset)
(P.34)
41
KX-TG1843ALS / KX-TGA122AZS / KX-TGA121AZS
Summary of Contents for KX-TG1843ALS
Page 15: ...6 HOW TO REPLACE THE HANDSET LCD 15 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 20: ...Cross Reference Check Point Base Unit P 25 20 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 22: ...Cross Reference Check Point Handset P 34 22 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 51: ...19 SIGNAL ROUTE 51 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 52: ...52 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 58: ...22 ENGINEERING MODE 22 1 Base Unit 58 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 61: ...22 2 Handset 61 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 65: ...24 CABINET AND ELECTRICAL PARTS BASE UNIT 65 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 67: ...26 CABINET AND ELECTRICAL PARTS CHARGER UNIT 67 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 69: ...27 2 KX TGA121AZS 69 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 71: ...28 3 Charger Unit 71 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 78: ...Memo 78 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...
Page 83: ...Memo 83 KX TG1843ALS KX TGA122AZS KX TGA121AZS ...