3.5 Information about the Physical CO Line Cards
86
Installation Manual
3.5.3
T1 Card (KX-TDA0187)
Function
1-port T1 CO line card. EIA/TIA standard compliant.
Accessories and User-supplied Items
Accessories (included):
none
User-supplied (not included):
RJ45 connector
Notes
•
Connect this optional service card to the CO line through NT1; do not connect to the CO line
directly.
•
T1 Card must be installed behind an FCC registered and UL or CSA-NRTL listed CSU.
•
To confirm the CO line connection, refer to "Confirming the CO Line Connection" in "3.14.1 Starting
the PBX".
CAUTION
T1 ports are SELV ports and should only be connected to SELV services.
Switch Settings
Switch
Type
Usage and Status Definition
A/B
Slide
Keep the switch at default A position. Do not change the position of
this switch.
LEDs
RJ45
AB
To NT1