3.13 Power Failure Connections
162
Installation Manual
3.13 Power Failure Connections
3.13.1 Power Failure Connections
Connection
Power Failure Connection connects a specific SLT and a CO line in the event of power failure. The following
analog CO line and extension cards can be used for Power Failure Connections:
•
Analog CO line cards:
LCOT16 (4 PFT ports) and LCOT8 (2 PFT ports)
•
Extension cards:
MSLC16 (4 PFT ports), SLC16 (4 PFT ports), DHLC8 (2 PFT ports) and SLC8
(2 PFT ports)
To 1 analog CO line card, connect only 1 extension card.
Note
By programming the PBX, a CO line conversation established during power failure can be maintained
even when the power returns and the connection is switched back to the normal configuration from the
Power Failure Connection. However, if no special programming is performed, the connection will be
dropped when power returns.
Accessories and User-supplied Items
Accessories (included):
none
User-supplied (not included):
RJ11 connectors
CO Line Card
(e.g., LCOT8)
Extension Card
(e.g., SLC8)
R2
R1
T1
T2
T2
T1
R1
R2
RJ11
To CO line
To SLT
Summary of Contents for KX-TDE110
Page 38: ...1 4 Specifications 38 Installation Manual ...
Page 44: ...2 1 Information about the Activation Keys 44 Installation Manual ...
Page 166: ...3 14 Starting the PBX 166 Installation Manual ...
Page 186: ...5 1 Troubleshooting 186 Installation Manual ...
Page 187: ...Installation Manual 187 Index ...
Page 191: ...Index Installation Manual 191 ...