3.8 Connection of Extensions
Installation Manual
119
3.8
Connection of Extensions
3.8.1
Maximum Cabling Distances of the Extension Wiring
(Twisted Cable)
Notice
The maximum cabling distance may vary depending on the conditions.
"
" indicates that the extension card supports the terminal.
* The maximum cabling distance from the PBX is the same even when the KX-T7600 series DPT is the
master DPT on the Digital XDP connection.
PT-interface CS
DPT
APT
DSS Console
SLT
DHLC8 Card
MSLC16, SLC16,
SLC8 Cards
DLC16, DLC8 Cards
Cable
Maximum Distance
26 AWG:
500 m (1640 ft)
24 AWG:
720 m (2362 ft)
22 AWG:
830 m (2723 ft)
CAT 5:
720 m (2362 ft)
Cable
Maximum Distance
26 AWG:
140 m (459 ft)
24 AWG:
229 m (751 ft)
22 AWG:
360 m (1181 ft)
CAT 5:
229 m (751 ft)
Cable
Maximum Distance
26 AWG:
698 m (2289 ft)
24 AWG:
1128 m (3700 ft)
22 AWG:
1798 m (5897 ft)
CAT 5:
1128 m (3700 ft)
Other PT (DPT/APT)
and DSS Console
SLT
KX-T7600 Series DPT*
Cable
Maximum Distance
26 AWG:
222 m (728 ft)
24 AWG:
347 m (1138 ft)
22 AWG:
500 m (1640 ft)
CAT 5:
347 m (1138 ft)