![Panasonic KX-NS8188 Installation Manual Download Page 59](http://html.mh-extra.com/html/panasonic/kx-ns8188/kx-ns8188_installation-manual_256356059.webp)
Category
Setting Item
Value Range
Setting Value
SIP Account / User
Name—From
100–99999
Set the SIP Account /
User Name start number
for the Trunk Adaptor
referring to the SIP
Authentication ID (SIP
Port Property) of the
Trunk Adaptor’s first
port. The default start
number is 401.
Port Property - Virtual
SIP Gateway—Calling
Party
From Header - User Part
User Name,
Authentication ID,
PBX-CLIP
Select
PBX-CLIP
.
DDI/DID
PBX Configuration—[10-2] CO & Incoming Call—DIL Table & Port Settings
Category
Setting Item
Value Range
Setting Value
DIL Table & Port
Settings—DDI / DID /
TIE / MSN
DDI/DID/TIE/MSN
Remove Digit
0–15
Specify the number of
digits of the SIP
Authentication ID. For
example, if the SIP
Authentication ID is 401,
select 3.
Installation Manual
59
4.5 Programming for the KX-NS1000