Using an EXtra Device Port
SLT
Master DPT
Slave DPT
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
2-conductor wiring cord
Connect pins "T" and "R".
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
To DLC8/DLC16 card
To DHLC4 card
(for connection of SLT)
To SLT
Slave DPT
Master DPT
Back View of DPTs
To DLC8/DLC16 card
To DHLC4 card
(for connection of SLT)
TO MAIN UNIT
/ PABX
TO MAIN UNIT
/ PABX
TO TEL
TO TEL
Cable Maximum
Distance
26 AWG: 30 m (98 ft)
24 AWG: 50 m (164 ft)
22 AWG: 60 m (196 ft)
CAT 5:
50 m (164 ft)
94
Installation Manual
Document Version 2011-10
3.8.3 Digital EXtra Device Port (Digital XDP) Connection