1.3.2 Characteristics
Terminal Equipment Loop Limit
•
PT: KX-DT300/KX-T7600 series DPT: 90
W
; all other DPTs/APTs:
40
W
•
SLT: 600
W
including set
•
Doorphone: 20
W
•
CS: 65
W
Minimum Leakage Resistance
15 000
W
minimum
Maximum Number of Extension
Instruments per Line
1.
for PT or SLT
2.
by Parallel or eXtra Device Port connection of an APT/DPT and
an SLT
3.
by Digital eXtra Device Port connection of 2 DPTs and an SLT
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
Central Office Loop Limit
1600
W
maximum
Hookswitch Flash Timing Range
24 ms to 2032 ms
Door Opener Current Limit
24 V DC/30 V AC, 1 A maximum
External Relay Current Limit
24 V DC/30 V AC, 1 A maximum
External Sensor Current Limit
Power to the external sensor is provided from the EIO4 card and must
be grounded through the EIO4 card. For the connection diagram, refer
to "3.7.3 EIO4 Card (KX-TDA0164)". The PBX detects input from the
sensor when the signal is under 100
W
.
Paging Terminal Impedance
600
W
MOH (Music on Hold) Terminal
Impedance
10 000
W
Document Version 2011-10
Installation Manual
27
1.3.2 Characteristics
Summary of Contents for KX-NCP500
Page 18: ...18 Installation Manual Document Version 2011 10 Table of Contents...
Page 130: ...130 Installation Manual Document Version 2011 10 5 1 5 Troubleshooting by Error Log...
Page 131: ...Section 6 Appendix Document Version 2011 10 Installation Manual 131...
Page 136: ...136 Installation Manual Document Version 2011 10 6 1 4 PBMPR Software File Version 5 0xxx...
Page 137: ...Index Document Version 2011 10 Installation Manual 137...
Page 141: ...Document Version 2011 10 Installation Manual 141 Notes...