2.4.4. SERVICE FUNCTION TABLE
Code
Function
Set Value
Effective Range
Default
Remarks
501
Pause time set
X 100 msec
001~600
30
----------------
502
Flash time set
01~99 X 100 msec
01~99
100
----------------
503
Dial speed select
1:10 pps 2:20 pps
1, 2
1
----------------
511
Vox sense
1:High 2:Low
1, 2
1
When the TAM or EXT TAM
does not stop recording the
ICM because noise is detected
on the telephone line, change
this setting to "LOW".
514
Bell detect time set
1~9 X 100 msec
1~9
600
----------------
520
CED frequency select
1:2100 Hz 2:1100 Hz
1, 2
1
See Symptom/
Countermeasure Table for
long distance and international
calls in 2.3.3.1. Defective
Facsimile Section.
521
International mode select
1:ON 2:OFF
1, 2
1
See Symptom/
Countermeasure Table for
long distance and international
calls in 2.3.3.1. Defective
Facsimile Section.
522
Auto standby select
1:ON 2:OFF
1, 2
1
The resolution reverts to the
default when transmission is
complete.
523
Receive equalizer select
1:ON 2:OFF
1, 2
2
When the telephone station is
far from the unit or reception
cannot be performed correctly,
adjust accordingly.
524
Transmission equalizer select
1:0.0km / 2:1.8km
3:3.6km / 4:7.2km
1~4
1
----------------
550
Memory clear: To reset the value to the default one, except the top margin (853)
and left margin (854).
"START" input"
552
DTMF single tone test
1:ON 2:OFF
1, 2
2
See 2.5. TEST FUNCTIONS.
553
Monitor on FAX communication
select
1: OFF 2:PHASE B
3:ALL
1~3
1
Sets whether to monitor the
line signal with the unit´s
speaker during FAX
communication or not.
554
Modem test
See 2.5. TEST FUNCTIONS.
555
Scan check
See 2.5. TEST FUNCTIONS.
556
Motor test
0
See 2.5. TEST FUNCTIONS.
557
LED test
See 2.5. TEST FUNCTIONS.
558
LCD test
See 2.5. TEST FUNCTIONS.
559
Document jam detection select
1:ON 2:OFF
1, 2
1
See 2.2.1. Paper Jam.
561
KEY test
See 2.5. TEST FUNCTIONS.
570
BREAK % select
1:61% 2:67%
1, 2
2
Sets the % break of pulse
dialing accordingly PBX.
571
ITS auto redial time set
X number of times
00~99
00
Selects the number of time that
ITS is redialed (not including
the first dial).
572
ITS auto redial line disconnection
time set
X second
001~999
65
Sets the interval of ITS
redialing.
573
Remote turn-on ring number set
X number of rings
01~99
15
Sets the number of rings
before the unit starts to receive
a document in the TEL mode.
590
FAX auto redial time set
X number of times
00~99
2
Selects the number of redial
times during FAX
communication (not including
the first dial).
591
FAX auto redial time disconnection
time set
X second
001~999
65
Sets the FAX redial interval
during FAX communication.
592
CNG transmit select
1: OFF 2:ALL
3:AUTO
1~3
2
Lets you select the CNG output
during FAX transmission. ALL:
CNG is output at phase A.
AUTO: CNG is output only
when automatic dialing is
performed. OFF: CNG is not
output at phase A.
593
Time between CED and 300bps
1: 75 msec 2:500
msec 3:1 sec
1~3
1
See Symptom/
Countermeasure Table for
long distance and international
calls in 2.3.3.1. Defective
Facsimile Section.
83
KX-FP101AL
Summary of Contents for KX-FP101AL
Page 7: ...1 11 ITU T Test Chart Actual size 7 KX FP101AL ...
Page 9: ...1 12 2 CONTROL PANEL 9 KX FP101AL ...
Page 18: ...1 14 12 REPLACING THE FILM CARTRIDGE 18 KX FP101AL ...
Page 19: ...19 KX FP101AL ...
Page 29: ...2 3 3 TROUBLESHOOTING ITEMS TABLE 29 KX FP101AL ...
Page 30: ...2 3 3 1 Simple Check List 30 KX FP101AL ...
Page 32: ...2 Document JAM 32 KX FP101AL ...
Page 36: ...6 Paper JAM 7 Multiple feed and skew 36 KX FP101AL ...
Page 39: ...Fig C 12 A blank page is received 39 KX FP101AL ...
Page 43: ...2 3 3 3 1 Defective facsimile section 1 Transmit problem 43 KX FP101AL ...
Page 50: ...50 KX FP101AL ...
Page 51: ...51 KX FP101AL ...
Page 52: ...52 KX FP101AL ...
Page 53: ...53 KX FP101AL ...
Page 54: ...54 KX FP101AL ...
Page 55: ...55 KX FP101AL ...
Page 56: ...56 KX FP101AL ...
Page 57: ...57 KX FP101AL ...
Page 65: ...I O and Pin No Diagram 65 KX FP101AL ...
Page 67: ...67 KX FP101AL ...
Page 68: ...68 KX FP101AL ...
Page 69: ...2 3 3 4 2 Check the Status of the Digital Board 69 KX FP101AL ...
Page 73: ...2 Troubleshooting Flow Chart 73 KX FP101AL ...
Page 75: ...2 3 3 7 Operation Panel Section 1 No key operation 2 No LCD indication 75 KX FP101AL ...
Page 78: ...2 3 3 9 CIS Contact Image Sensor Section Refer to 6 4 4 SCANNING BLOCK 78 KX FP101AL ...
Page 79: ...79 KX FP101AL ...
Page 80: ...2 3 3 10 Thermal Head Section Refer to 6 4 3 THERMAL HEAD 80 KX FP101AL ...
Page 93: ...2 4 7 3 PRINTOUT EXAMPLE 93 KX FP101AL ...
Page 94: ...94 KX FP101AL ...
Page 97: ...2 5 3 PRINT TEST PATTERN 1 Platen roller Reference pattern 97 KX FP101AL ...
Page 98: ...2 Left margin Top margin Reference pattern 98 KX FP101AL ...
Page 99: ...3 Thermal head 1 dot Reference pattern 99 KX FP101AL ...
Page 122: ...6 3 2 MEMORY MAP 122 KX FP101AL ...
Page 134: ...134 KX FP101AL ...
Page 144: ...6 4 6 3 2 Transmitting documents 6 4 6 3 3 Receiving FAX 144 KX FP101AL ...
Page 145: ...6 4 6 3 4 Copying 145 KX FP101AL ...
Page 163: ...163 KX FP101AL ...
Page 171: ...7 1 MEMO 171 KX FP101AL ...
Page 172: ...172 KX FP101AL ...
Page 176: ...9 1 MEMO KX FP101AL 176 ...
Page 180: ...11 1 MEMO KX FP101AL 180 ...
Page 182: ...12 1 MEMO KX FP101AL 182 ...
Page 184: ...13 1 MEMO KX FP101AL 184 ...
Page 186: ...14 1 MEMO KX FP101AL 186 ...
Page 188: ...15 1 MEMO KX FP101AL 188 ...
Page 189: ...16 TERMINAL GUIDE OF THE IC S TRANSISTORS AND DIODES 189 KX FP101AL ...
Page 190: ...17 FIXTURES AND TOOLS 190 KX FP101AL ...
Page 192: ...18 2 UPPER CABINET SECTION 192 KX FP101AL ...
Page 193: ...18 2 1 PICK UP BASE SECTION 193 KX FP101AL ...
Page 194: ...18 3 LOWER P C B SECTION 194 KX FP101AL ...
Page 195: ...18 4 MOTOR SECTION 195 KX FP101AL ...
Page 196: ...18 5 ACTUAL SIZE OF SCREWS AND WASHER 196 KX FP101AL ...
Page 197: ...19 ACCESSORIES AND PACKING MATERIALS 197 KX FP101AL ...