Parameter
Function
Sensitivity
It is sensitivity of brightness as VMD is more possible to be
trigger with high sensitivity. You can set up to four areas. The
range is 0 - 100. The recommenced value is 30 - 70. The default
is 60.
Threshold
It is to check target object area related to detection area. The
lower the area threshold, the easier to trigger VMD. You can set
up to four areas. The range is 0 - 100. The recommenced value
is 10 - 50.
Waveform
Red means motion detect is triggered. Green means motion
detect is not triggered.
Delete All
Clear all areas.
Delete
Delete selected area.
Tampering
4.4.1.2
The tampering interface is shown as in Figure 4-29 and Figure 4-30.